通风各工种操作规程

2024-04-30

通风各工种操作规程(精选4篇)

篇1:通风各工种操作规程

监测工岗位责任制 ················································································· 1 便携仪发放岗位责任制 ········································································· 1 导通人员操作规程 ················································································· 1 火工品搬运操作规程 ············································································· 1 火药库管理员操作规程 ········································································· 2 放炮员操作规程 ····················································································· 2 掘进放炮操作规程 ················································································· 4 采煤工作面放炮员操作规程 ································································ 10 防尘工操作规程 ··················································································· 14 防火工操作规程 ··················································································· 15 测风员操作规则 ··················································································· 15 木工操作规程 ······················································································· 16 注水工操作规程 ··················································································· 17 测尘工操作规程 ··················································································· 17 微机工操作规程 ··················································································· 18 拆除安装工操作规程 ··········································································· 19 盲巷管理工操作规程 ··········································································· 19 瓦检工操作规程 ··················································································· 19 光学甲烷测定仪校验操作规程 ···························································· 20 监测工操作规程 ··················································································· 20 便携仪校验操作规程 ··········································································· 21 木工操作规程 ······················································································· 21 打钻工操作规程 ··················································································· 22 防尘工操作规程 ··················································································· 23 防火工操作规程 ··················································································· 23 井下瓦斯抽放泵工操作规程 ································································ 24

监测工岗位责任制

1、熟练掌握弱电及监测系统的有关知识,精通维修技术。

2、按要求检查检修监测装置,吊挂监测线子。

3、每周校验监测分站及瓦斯传感器。

便携仪发放岗位责任制

1、掌握仪器性能及充电方法。

2、按牌对号发放,不合格的不得入井。

3、仪器回收是要检查仪器是否完好,并及时上架充电。

4、发现仪器损坏,及时向有关人员汇报。

5、经常和维修人员取得联系,发现问题及时解决。

导通人员操作规程

1、雷管进库后,必须由导通人员验查,雷管包装是否完好,是否缺段,确认无误后,方可进行导通。

2、雷管的导通必须在专用导通室内进行,必须由导通人员亲自打开雷管盖,其他人员不得随便打开雷管箱盖。

3、由导通人员用雷管测试仪逐一检查不同断号雷管电阻的大小,必须符合(3.5—6.3欧姆),查出不合格的雷管必须跟当班库管员讲明不合格雷管的品种数量及出厂日期,然后由库管员填入报废雷管登记薄。

火工品搬运操作规程

1、炸药雷管到矿后,由下药人员根据移拨单验查炸药雷管的品种数量及包装是否完好,确认无误后,方可装卸。

2、装卸时要轻装轻放,严禁撞击,装卸后由下药人员跟运输区联系,及时地把炸药雷管打下井,由下药人员安全地把炸药雷管运送到井下药库。

3、炸药雷管到库后,必须整齐的把炸药雷管放进各自壁槽内,并向当班库管员讲明下药的品种、数量,由库管员验收入帐。

火药库管理员操作规程

1、炸药雷管到库后,库管员必须验收登记炸药雷管的品种数量,包装是否完好,雷管是否缺段,确认无误后,方可进入各自的壁槽内。

2、炸药雷管进库后,库管员必须按照先进发,后进后发,防止积压。

3、库管员必须把导通合格的雷管进行编号,编号要在专用编号室内进行,必须专人专号,坚持“七项制度”、“五不发”的原则,根据当班计划进行对号发放。

4、库管员回收退库雷管时,必须验查,做到帐卡相符。

放炮员操作规程

一般规定:

1、井下放炮工作必须由有两年以上的工龄的专职放炮员担任,并经过专门培训、考试合格,方可持证上岗。

2、放炮员必须熟悉爆破器材的性能和《煤矿安全规程》中有关条文的规定。

3、接触爆破材料的人员应该穿棉布或其它抗静电衣服,不准穿带静电的化纤衣服。

4、放炮员下井前要领取符合规定的瓦斯报警仪、放炮器和放炮母线等。不符合规定的放炮器不准下井使用;放炮员必须严格执行集团公司、矿制定的爆破器材领用退的管理制度。

5、使用爆破器材的规定

(1)禁止使用冻结或半冻结的硝化甘油炸药,并禁止将其折断、切割、揉搓、扎眼或撕下药包纸。

(2)不得使用含水超过0.5%的铵梯炸药。(3)井下严禁使用黑火药。

6、在有瓦斯或煤尘爆炸危险的煤层中掘进时,必须使用取得产品许可证的煤矿许用炸药和煤矿许用瞬发及毫秒延期电雷管。延期电雷管第一段与瞬发电雷管不得互相代替使用。不同厂家生产的和不同型号的电雷管不得混杂使用。

7、在发出使用电雷管前,必须逐个做全电阻和导通检查,严禁发放不通电和电阻不合格的电雷管。

8、用放炮方法贯通巷道时,必须严格遵守作业规程有关的规定。

9、在开凿或延深立井井筒,爆破材料运送到井底工作面和在井筒内装药时,除负责装药、放炮人员和水泵司机外、其他人员都必须撤到地面或生产水平。

10、严禁采用糊炮或明火放炮;严禁用炮崩落卡在溜煤眼中煤矸,如确需崩眼必须编制措施,报矿总工程师批准。

11、在高瓦斯或煤(岩)与瓦斯突出的掘进工作面放炮,必须严格执行制定的特殊安全措施。

掘进放炮操作规程

一、炮前准备工作

1、爆破材料的运送与存放

(1)电雷管必须由放炮员亲自运送,炸药可由放炮员或在放炮员监护下,由经过培训的放炮员助手运送。

(2)领取的电雷管和炸药应分别装在不同的坚实的非金属容器内。严禁将爆破材料装在衣袋内。领到爆破材料后须直接送到工作地点,严禁中途逗留。

爆破材料运送到工作地点后,炸药、雷管仍应分别存放在木制后其他绝缘材料制成的专业炮药箱内。

炮药箱应放到警戒线以外支护完好的、干燥的安全地点,并离开电气设备和电缆、电线。

炮药箱要加锁,钥匙由放炮员随身携带。

(3)严禁用刮板输送机或胶带输送机运送爆破材料。

(4)放炮前需准备好足够使用的引药、炮泥和水炮泥,并整齐放置在符合规定的地点。

2、检查放炮器与放炮母线。放炮器要完好可靠,电压符合要求;放炮母线长度符合规定,并无断头和短路,绝缘皮有破损处应及时处理。

3、准备好炮辊、岩(煤)粉掏勺等放炮器具。

4、引药的装配

(1)装配引药必须在顶板完好、支架完整,避开电气设备和导电体的放炮地点附近进行,严禁坐在炮药箱上装配引药。(2)从成束的电雷管中抽取单个电雷管时,不得手拉脚线硬拽管体,也不得手拉管体硬拽脚线;应将成束的电雷管脚线顺好,拉住前端脚线将管体抽出。抽出后的单个电雷管的脚线末端要扭结。

(3)装配引药时,必须防止电雷管受震动或冲击以及折断电雷管脚线和损坏脚线绝缘层。

(4)电雷管只许由药卷的顶部装入。先用木或竹制的炮针在药卷顶端中心扎略大于雷管直的孔眼,然后将雷管插入孔眼,并将脚线在药卷上套一个扣,并将剩余脚线全部缠绕在药卷上,同时将脚线末端扭结。

每个药卷内只准插入一个电雷管。

(5)装配好的引药要整齐摆放在炮药箱附近符合规定的安全地点,并且清点数量、掩盖好,不得丢失,不准随意地乱放。

4、装药前应做以下工作

5、(1)放炮员、班组长和瓦斯检查员对迎头附近20米范围内进行瓦斯检查,严格执行装药前及放炮后的“一炮三检”制度。(2)班组长负责对工作面附近洒水灭尘。

(3)班组长负责对迎头支架进行加固,保证支架完好。(4)用压风或掏勺将炮眼内的煤(岩)粉清理干净。(5)凡有下列情况之一的不准装药:

(1、)掘进迎头空顶距离超过作业规程规定,支架处于不完好状态。(2、)装药地点20米范围内,有未清除的煤、矸和矿车、机电设备或其他物体阻塞巷道端面1/3以上时(3、)装药地点20米范围内风流中沼气浓度达到1%和煤尘堆积飞扬时。

(4、)炮眼内发现异状、温度骤高骤底、炮眼出现塌陷、裂缝、有压力水、瓦斯突增等。

(5、)工作面风量不足或局扇停止运转时。(6、)炮眼内煤(岩)粉为清除干净时。

(7、)炮眼深度、角度、位置等不符合作业规程规定时。(8、)装药地点有片帮冒顶危险时。(9、)发现瞎炮、残炮未处理时。

6、装药

(1)放炮员必须按照爆破说明书进行装药。各炮眼的雷管段号要与爆破说明书规定的起爆顺序相符合。

(2)装药时要一手拉脚线,一手拿木制或竹制炮棍将药卷轻轻推入眼底,用力要均匀,使药卷紧密相接。装药完后要将两脚线末端扭结。(3)起爆方式分正向起爆和反向起爆。正向起爆的引药最后装,引药及所有药卷的聚能穴都朝向眼外。

(4)无论采用何种起爆方式,引药都应装在全部药卷的一端,不得将引药夹在两药卷中间。

(5)在有煤尘与瓦斯爆炸危险的掘进工作面严禁采用反向起爆的方式。

(6)在同一次装药放炮工作面,严禁装入两种不同性质的炸药。

7、封泥应用水炮泥以及不燃性的可塑性的材料制成。禁止使用块状 材料或可燃性材料做封泥。未封泥或封泥不足和不严的炮眼禁放炮。

8、封泥的装填结构与操作应按如下规定:

(1)装填炮泥时,一手拉脚线,一手用炮棍轻轻推填炮泥,并捣实。(2)封泥装置结构是:先装填水炮泥一至数个,在水炮泥外端再填塞炮泥。

(3)装填水炮泥不要用力过大,以防压破。装填水炮泥外端的炮泥时,先将炮泥贴紧眼壁上,然后轻轻捣实。

9、炮眼封泥量的规定:

(1)炮眼深度小于0.6米时,不准装药放炮。

(2)炮眼深度0.6—1.0米时,封泥长度应不小于炮眼深度的1/2。(3)炮眼深度超过1.0米时,封泥长度不得小于0.5米。

(4)在有突出危险的掘进工作面中,所有不装药的炮眼都应用炮泥填实。

10、放炮母线的敷设:

(1)放炮母线必须使用导电性能好的绝缘双线,禁止用钢轨、金属管、电缆等导体当作回路或母线使用。

(2)放炮母线与电缆、信号线应分别悬挂在巷道两侧,如果必须挂在同一侧时,放炮母线必须挂在电缆等线的下方,并应保持0.3米以上的间距。

(3)放炮母线必须由里向外敷设。其两端头在与脚线、放炮器连接前必须扭结短路。

(4)放炮母线的敷设长度要符合作业规程有关规定。

11、连线方式与连线要求:

(1)各炮眼雷管脚线的连接方式应按作业规程要求,雷管脚线与母线的连接必须由放炮员操作。

(2)电雷管脚线和连接线、脚线与脚线之间的接头,都必须悬空,不得与任何物体接触。

12、在连线放炮前,必须在距迎头20米范围内进行第二次瓦斯检查。在瓦斯浓度不超限的情况下,方连线放炮。

13、放炮前要做好警戒工作:(!)班组长必须布置专人担任警戒。(2)警戒点要符合作业规程规定。

(3)各警戒点除警戒人员外,还要设置警示牌、栏杆或拉绳标志。(4)放炮前工作面所有人员必须撤至作业规程规定的最小安全距离以外的安全地点。

14、放炮:

(!)连线后,放炮员必须最后退出迎头,并沿途检查放炮母线是否符合要求。

(2)放炮员进入放炮地点后,随即发出第一次放炮信号。(3)放炮员接到组长的放炮命令后,将母线与放炮器相接,并将放炮把手插入放炮器,转至充电位置。

(4)第二次发出放炮信号。再走10—15秒,放炮器指示灯亮稳定后,将放炮器手把转回放电位置,将电雷管起爆,、,(5)起爆后,将母线从放炮器接线柱上摘下,并扭结短路,拔下的 放炮器手把有放炮员随身携带,不得转交他人。

15、放炮后验炮:

(1)迎头排除烟后,班组长、放炮员、瓦检员立即进入迎头,由外向里顺序检查巷道支护情况,发现问题应及时处理。(2)检查瓦斯浓度,符合规定时方可开动电气设备。(3)检查工作面爆破情况,并找除悬矸危岩。

(4)通电后若未起爆,放炮员必须取下放炮手把,将母线摘下扭结短路。至15分钟后,方可沿线检查,若为短路、短线、连线不良等原因,应立即处理:若确认非线路原因,且不能确定瞎炮位置时,可采用分段连接,重新起爆,逐段排除。

(5)检查处理瞎炮或重新连炮前,必须设专人观察顶、帮情况,在确认安全前提下,方可进行操作处理。

16、处理瞎炮

(1)处理瞎炮时,必须在距瞎炮眼0.3米处,重新平行打眼装药放炮,新炮眼深度要超过瞎炮孔深度:打眼时应在瞎炮眼外端口插入炮棍作为导向标志。

(2)严禁用镐刨、手拉或压风吹的方法处理瞎炮:严禁将炮眼残底继续打深,用打眼的方法向外掏药。

(3)在处理瞎炮前,严禁在该地点进行与处理瞎炮无关的工作。(4)处理瞎炮之后,放炮员必须详细检查炸落的饿煤矸,找出未爆药包和雷管。

17、放炮结束后,放炮员要报告班长,由班长解除警戒后,其他人员 方可进入工作面作业。

18、装药的炮眼必须当班放完,遇有特殊情况时,放炮员必须在现场向下一班放炮员交代清楚。

19、放炮后,应将放炮母线、放炮器等收拾整理好。

20、清点剩余雷管、炸药,填好消耗单,在核清领取数量与使用剩余的数量相符后,经班长签字,将当班剩余材料交回药库销号。严禁私藏爆破器材。

21、升井后,将放炮器、瓦斯报警器等交回规定的存放处。

采煤工作面放炮员操作规程

1、采煤工作面放炮员必须由责任心强、熟悉通风、瓦斯和爆破材料及放炮技术、经培训、考试合格,持有放炮员合格证专职人员担任。

2、严格遵守《煤矿安全规程》有关通风、瓦斯、火药管理等规定,切实执行工作面作业规程及爆破说明书和本操作规程。

3、严格执行“一炮三检”和“三人连锁换牌”放炮制度,工作面放炮前,放炮员、班组长、瓦斯检查员和兼职安监员都应该在现场。

4、在高瓦斯或具有煤尘爆炸危险的煤层中放炮时,必须采用正向爆破,严禁采用反向爆破。

5、严禁采用糊跑、明火、普通导爆索或非电导爆管放炮。

6、放炮与回采其他工序平行作业时,必须按照放炮的安全距离规定执行,否则应停止放炮。

7、在地质变化地带、冒顶区安全出口等处的顶板破碎、煤层松软、容易冒顶片帮的地段,要少装药、放小炮或不放炮。

8、运送炸药、装药封泥由兼职的放炮员助手进行。

9、炸药的存放:

(1)炸药在工作面临时存放,必须放置在距工作面煤壁30米以外顶板完好、支架完整、远离电器设备、不潮湿的安全地点。(2)炸药箱内只准存放炸药并上锁,严禁存放其他物品。(3)不准任何人在存放炸药的地点休息。(4)放炮器必须由放炮员随身携带。

10、放炮员的工作程序

准备(领取工具和爆破材料

运送爆破材料

存放爆破材料

装配引药)检查处理

放炮操作(装药

设警戒

连线

放炮

炮后检查

撤警戒)收尾工作。

11与区队联系确定当班使用雷管数量,填写领取单。严禁携带不合格的瓦斯检定器下井。

12、领取并检查防爆放炮器。

(1)用放炮器钥匙扭到充电位置,氖灯要发亮。(2)严禁用短路的方法检查放炮器。

(1)用放炮器钥匙扭到充电位置,氖灯要发亮。(2)严禁用短路的方法检查放炮器。(3)放炮器完好,电池有电。

13、领取放炮母线。

(!)必须使用橡胶铜芯或聚氯乙烯铜芯双线电缆。(2)放炮母线接头除锈、扭结并用绝缘带包好。

14、领取掏勺、木扦、木或竹质炮辊,炮辊的直径应略大于药卷的直径。

15、领送电雷管。

(1)只准领取毫秒延期电雷管,毫秒雷管最后一段的延期时间不得超过130秒。

(2)当面点清电雷管数量。

(3)严禁使用延期性电雷管、非电导爆管。(4)电雷管必须由放炮员亲自携带,不得乘车。(5)领到雷管后,应直接运到工作地点,严禁中途逗留。

16、装配引药

(1)只准有放炮员装配引药,不得由其他人代替。

(2)必须在顶板完好、支架完整、远离电气设备和导电体的巷道内装配引药。

(3)严禁坐在炸药箱上装配引药。

(4)从成束雷管中抽出单个电雷管时,应将成束的电雷管脚线顺好,拉出前端脚线将电雷管拉出,不得手拉脚线硬拽脚线,一个管线只准装一个管体。

(5)装配引药,用木扦或竹扦在药卷端头扎好大于雷管。(4)警戒的安全距离应超过放炮位置20米。

21、检查及处理:在连线和放炮前,放炮员和班组长、瓦斯检查员对放炮的地点进行第二次检查,对查出的问题应及时处理。有下列情 况之一时,不准备进行连线放炮。

(1)放炮地点20米以内风流中瓦斯浓度达到1%;(2)存在第十七条的各项问题未处理或处理后又出现时;(3)没按第二十条的规定设好警戒;(4)放炮母线不足50米;

(5)应掩盖维护好的设施未进行掩盖和维护;(6)分段放炮时,崩倒的支架未扶好。

22、连线:

(1)要按照作业规程规定的放炮顺序和连线方法连线放炮;(2)严格执行谁连线谁放炮,即放炮母线连电雷管脚线、检查线路及充电都必须由放炮员本人操作。

(3)工作面布置的单排、双排、三花或五眼的连线都采用大串联法,最后剩下的两条脚线在未和母线连接前扭结成短路; 母线未和脚线前,两端必须扭结成短路。

(4)母线与脚线连接后,再沿线检查母线,放炮员最后退出放炮地点。

23、放炮:

(1)母线与电雷管脚线连接后,放炮员既吹第一次口哨并大叫喊“要放炮啦”;

(2)放炮员沿路检查线路,第二次吹口哨并大声叫喊“快放炮啦”;(3)放炮员到达放炮的警戒地点后,将母线连接在放炮器的接线端拧紧,这时第三次吹口哨并大声叫喊“放炮啦”,等待30秒确认无人 后,用钥匙将开并转到充电位置,待氖灯闪亮稳定,将开关钥匙转到原来放电位置启爆。

(4)炮响后,首先取下放炮器钥匙,然后将母线从放炮器上摘下并打结短路。

24、炮后检查:

(1)放炮员会同班组长、瓦斯检查员进行放炮后的检查工作,检查及处理内容同第十七、二十一条;

(2)通电后若没有爆炸。至少15分钟后,放炮员方可沿线路检查不炸的原因;

(3)确属因连接不良造成不炸时,可以重新连接放炮;(4)若确属瞎炮,应按《煤矿安全规程》第315条处理。

25、装药的炮眼必须当班放炮完毕。若遇特殊情况无法当班放完时,必须在现场向下班放炮员交清情况。

26、在本班放完炮、吹散炮烟并经组长同意后,放炮员须吹长哨叫喊“放完炮啦”,由班长亲自撤警戒后才能让其他人员进入工作面作业。

27、收拾整理好工具,存放规定地点或亲自携带收藏。

28、点清剩余电雷管、炸药、填写消耗单并须经班组长签字。当班要办好爆破材料退还手续,不准私藏电雷管及炸药。

29、向下班放炮员交班,介绍当班工作情况。

30、上井后要将瓦斯检定器交回通风区仪器、仪表班。

防尘工操作规程

1、下井前要先准备各种所用工具和一定数量尺寸的管子、三通、阀门、螺丝、垫片,准备入井。

2、上井、下井管子装车要固定好,且要按矿运管处的作业规程,持证上岗。

3、安设防尘管路时,主要巷道100米设一处三通、阀门,辅助巷道要每50米设一处三通、阀门、管子、接头、螺丝、垫片要放到位,螺丝要紧到位,防尘管路要安设吊挂平直、牢固,接头严密不漏水。

4、拆除防尘管路是,要把所有拆除的管子、三通、阀门、螺丝、垫片装车固定好,全部升井入库。

防火工操作规程

1、风门或封闭墙四周掏槽不少于200㎝,见硬帮硬底与煤岩接实。

2、砌墙时沙浆比例按1:3:5配制,泥墙时按1:2配制。

3、砖墙必须三跑一丁层层带灰,灰缝饱满,不重缝、无瞎缝,墙面平整。

4、墙面要泥平,四周要抹唇边,唇边不少于200㎝。

5、砌好墙后,前后5米要清理干净,验收合格后方可交,风门交于木工,封闭交于盲巷工。

测风员操作规则

1、每次下井前,应配备风表、记时器、皮尺、记录手册以及瓦斯机、温度计等。并对各种仪表进行完好检查,保证正常使用。

2、测风地点应选择较为规范的断面,巷道与支护完好规整,前后十 米无障碍物,无拐弯。

3、量断面时,根据巷道的实际情况,选择正确度量方法,皮尺拉平拉紧,计算断面时不同支护形式的巷道应分别计算,不准估计。

4、根据风速的大小,选择测量范围相适应的风表。

5、测风时仪表的指针是否在零位,不在零位时应进行回零。

6、测风时移动应均匀,路线正确,风速应与风流方向垂直,测量结束时,应同时按下封表和秒表,既可读出数据。

7、倾斜巷道测风时,应注意测风角度。

8、测风时,注意风流方向,严禁风表出现倒转。

9、计算风量时,应进行风速矫正,方可进行风量计算。

10、每地点测风时,应不少于三次,取平均值。

木工操作规程

1、按分工范围认真巡回检查井下的风门临时木板封闭,发现有所损坏应向单位领导汇报并及时维修,2、风门的制作要符合标准,门扇要平整不漏风,要错位接缝,门扇厚度不得小于30㎜,还应根据需要能做出不同规格的特制门。

3、风门安装后,门框要“包边沿口”,有衬垫,四周接触严密,通车风门必须上闭锁绳,松紧程度以两道门不能同时打开为标准。

4、风门水沟要设挡风帘,管线预留孔要用黄泥堵实,风门5米之内无杂物。

5、临时木板封闭,应设在顶帮良好处,密闭四周要接触严密,木版排列要采用鱼鳞式搭接,强面要用黄泥勾缝,严密不漏风。

6、地面木工房要严禁烟火,保持干净整齐,木工房内的电器设备要严格按照规定使用。

注水工操作规程

1、施工前必须对所施工采区进行考查,制度注水方案,并对钻机进行一次调试,配齐相关设备方可入井。

2、安装钻机设备时,必须和有关单位联系,写出停电申请,方可停电安装通电。

3、在采区1号孔位固定钻机的位置,根据本采区1号孔为煤层布置情况,调整钻机角度(平行煤层布置最佳),孔深度应为工作面长度的三分之二,孔径50mm左右。

4、施工中,钻机必须有专人负责开机、停机,并有专人负责监督工作情况,发现问题及时调整。

5、钻孔达到规定深度后,立即退取钻杆,进行封孔。

6、封孔时,先下入封孔设备,在用黄泥、水泥进行风堵,风堵长度不低于2m.7、在对2号孔施工时,1、2号孔间距应为25`-30m之间,其它孔位依次类推。

8、在对煤体注水时,可根据煤体结构而定,可采用动压,静压两种方式注水。

9、安装流量表测定注水的大小。

测尘工操作规程

1、给仪器充好电,并检查测尘仪器的流量计、定时器和气泵气密性 是否正常。

2、调整好天平,准备称重。

3、将准备好滤纸集尘进行称重,并记录好编号和称重后的数据。

4、带仪器到井下各计划点将滤集尘装机进行实测,并记录好所测的地点、工序、时间、流量。

5、测后将所测过的滤纸集尘带到地面,先干燥,后称重,并记录好所测(滤纸、集尘)的编号、数据。

6、然后把所测(前、后)滤纸集尘的数据代入公式,计算出所测地点的粉尘浓度。

7、做好报表报集团公司、矿。

微机工操作规程

1、开机顺序:先打UPS约一分钟后,打开主机终端及终端显示屏;再打开打印机、图形显示器。

2、关机程序:(1)在主屏键入CTRL+K退出矿用软件,在SHPER—提示下键入EXIT+回车,退出系统管理,再按下中断按钮;(2)先关打印机→图形显示器→终端显示屏→终端→主机→UPS→电源。

3、正常运行期间,不得擅自退出矿用系统,不得擅自关机。

4、机器发出的报警应及时查明原因,详细记录,不得擅自废除机内原始文件。

5、(1)当供电电源出现故障时,立即向值班人员汇报,在UPS工作时间内处理不好时,则按顺序关机;(3)系统死机时可按下复位按钮,重新引导系统回到矿用软件管理系统;(4)系统发生故障而暂时处理 不好时,必须汇报并启动备用系统,以上问题应做详细记录。

拆除安装工操作规程

1、安装时,要按图纸要求将所用的风筒及线路等,一切设备在地面实验、验收合格后,方可下井。

2、按说明书要求把设备安装到位,一切运行正常后,方可通过验收移交使用人或单位并有记录。

3、回收时:(1)风筒要按数量按时回收到位,入库时,要经库房人员验收并有记录;(2)回收线路等设备时,要按规定与相关单位联系好,并按质按量回收到位,入库时,要经库房人员验收并有记录。

4、所安装的风筒及线路要严格按规定要求做好一切工作,风筒要两靠一直,线路每米一个吊挂点,设备要完好,位置要正确。

盲巷管理工操作规程

1、盲巷的管理人员按照区队安排带运栅拦材料及有关工具到所需要地点进行按标准打栅拦,清理封闭墙外和栅拦内外附近杂物。

2、每周巡回检查分管范围内的盲巷、封闭。

3、检查内容巷道封闭墙体、内外气体、压差、温度,并记录工作手册,填写检查记录和管理台帐。

4、检查结果及时向区队汇报。

瓦检工操作规程

1、下井前要对本仪器进行检查各部件和药品性能是否完好,要在工作场所范围内的新鲜风流对本仪器。

2、班中负责检查所有被检查的场所瓦斯浓度和温度,采掘工作面要 检查巷道风流中瓦斯浓度,发现问题要请示回报处理。

3、检查后要填写瓦斯记录牌板和瓦检员工作手册,进行回报。

4、当班人员要备用风筒和负责续接整理掘进工作面前端3节风筒和班中回报。

5、现场瓦检员对掘进工作面停电停风地点要及时撤出巷道内作业人员,并设置栅栏和警标,向矿、区调度回报。

6、严格执行现场交接班制度和交换本班存在问题并签字,班后要交清瓦斯机和检查记录手册。

光学甲烷测定仪校验操作规程

1、发放前要检查仪器是否完好,杜绝损坏的一起带下井。

2、及时清除一起表面的污物、灰尘。等由气路和缝隙进入一起。

3、检修时不得擅自更换不同型号的配件,必须与型号规格、参数及结构保持一致,以保证仪器的稳定性。

4、本仪器使用时要按规定时间校验或修理后,必须进行校正,使仪器的误差在规定的范围内,既:

测量范围(CH4)

允许误差(CH4)

0~1

±0.05

>1~4

±0.1

>4~7

±0.2

>7~10

±0.3

5、仪器必须装在皮套内,否则严禁入进井使用。

监测工操作规程

1、定期对各风站的电源箱防爆面进行完好处理。

2、要定期对各短电装置的防爆面进行完好处理。

3、要定期对瓦斯传感器进行调校。

4、调校瓦斯传感器应遵守先通空气后瓦斯的原则。

5、通气调校传感器时,一定要用流量计控制流量。

便携仪校验操作规程

1、校验仪器要轻拿轻放。

2、校验前要开机预热20分钟,然后看零点指示情况,若有偏差,调回零点。

3、零点稳定后,通入标准气样,看其显示值是否与标准气样相符,若不符,调其满度电位器,使其显示与标准气样符合。

4、校验的同时看仪器的报警点是否在1%时报警,若不报警,调其报警点电位器,使其在1%时报警。

5、以上工作完成后,仪器要及时上架充电。

木工操作规程

1、及时从料厂领取木板,木板厚度为6cm,宽150cm,长4m.2、制作时要先把木板按尺寸截好、刨平再开槽,大门的尺寸为1.36*1.65米,小门为0.6*1.2m.3、下门时要把门装在特制的车内,用铁丝捆牢防止松动。

4、井下须用绞车,要保持换牌才能操作。

5、安装时要检查防火砌的风门是否合格,不合格的风门严禁安装。

6、安装要先上门轴,门轴安装好后在当风门挂好后要检查风门是否 自动,如果风门完好,再把包边沿口钉好。

7、要每周把自己所辖区域内的风门检查一次,发现问题要及时汇报处理。

8、风门水沟要设置挡风帘,管线孔要用黄泥封实,清除风门5米内的杂物。

打钻工操作规程

1、钻机施工前,在地面接通电源,测试电机的灵敏度,调试合格后装车准备入井。

2、根据施工地点的实际情况,领取与其相符的电缆和电器设备,装车准备入井。

3、配齐施工所需各类工具。

4、钻机施工上下移动时,必须根据绞车管理制度友专人持证操作。

5、施工前钻机固定时,先选好孔位,垫好枕木,用升降器把钻机吊起,固定在枕木上,调好方向,打上压力柱,使钻机不至移动为止。

6、钻机位置固定好后,把钻杆角度调整到与煤层走向平行后,准备开机。

7、安装钻头、钻杆连接好水源后,紧好钻杆顶丝后,由专人负责开机、停机。

8、钻杆达到一定深度,拆降水源连接器,松动顶丝推出钻杆,堆放整齐。

9、封孔时把封孔器放入钻孔,先用黄泥封堵,再用水泥封孔,封孔长度不小于2米。

10、注水时,把封孔器连接到水量计量器上,再连接到固定的水源上,进行注水,注水量达到煤层所需时停止注水。

11、施工完毕后,把钻机设备、施工工具装车后打上井,入库备用。

防尘工操作规程

1、防尘工要做好井下各产尘点的防灭尘工作。

2、大巷要每5天,皮带巷要每3天冲刷或清扫一次,工作面要每班冲刷或清扫一次,必须冲刷井巷四周。

3、下井前先准备好所有工具和一定数量尺寸的管子、三通、阀门、螺丝、垫片等一并入井。

4、上下井管子装车固定好,且要按矿运管处的作业规程,持证上岗。

5、安设防尘管路时,主要运输巷道要每100米处设置三通、阀门,辅助巷道每50米设置一处三通、阀门、管子接头螺丝、垫片要齐全且垫片要放到位,防尘管路要吊挂平直、牢固,接头要严密不漏水。

6、拆除防尘管路时,要把所有拆除的管子、螺丝、垫片、三通等装车固定好,全部升井入库。

防火工操作规程

1、下井前根据提供的巷道断面备料。

2、联系矿车,把备料运输到设置门、墙的地点。

3、遇到绞车时要持证、换牌方可操作,开车前要检查绞车和大绳是否完好,不完好的绞车不准操作。

4、门墙的厚度一律为0.5米。

5、砌墙时要掏槽,见硬底硬帮,砖要一跑三丁,层层带灰,与煤岩 接牢,灰浆要饱满无重缝、瞎缝、空缝。砌墙沙灰比例3:1,泥墙沙灰比例为2:1。

6、三空要齐全。

7、墙砌好后要泥单,检查合格后把门墙前后5米清理干净,方可离开。

井下瓦斯抽放泵工操作规程

一、准备工作

瓦斯抽放泵超动前,必须首先检查供电,供水系统是否正常可靠,只有当两者可靠时,方可起动。

二、起动

1、检查电机与泵轴的同轴度。

2、用手转动联轴器,看转子转动是否灵活,有无卡住或磨擦现象。

3、检查各部分螺栓是否有松动现象。

4、检查轴泵的润滑脂是充足。

5、从进水管注入水、冲洗五分钟,同时用手转动转子,然后放出污水。

6、向泵腔内和填料处注入压力约为78-147Kpa的清水,注水时间约为30秒。

7、检查填料的松紧度,以密封水成滴滴下为宜。

8、打开进所阀门,开启开关,试验起动(约1分钟)检查电机的转向与水环泵的转向是否一致,如一致可起动运转。

三、运转

1、在正常启动后,在规定转速下,在工作范围人进行运转试验,时间不少于30分钟,试运转时检查轴封和联接部位的密封性,一切正常后,方可投入工作运转。

2、在泵运转中,应连续不断地向泵腔和填料处供水。

3、泵运转中应随时检查泵运转声音是否正常,泵是否振动。

四、停车

1、关闭进气管路上的阀门。

2、关闭电动机。

3、关闭各供水管路阀门。

4、打开放水管或泵体上的丝堵将水放掉。

5、长时间停车应关半监测系统,短期停车,可不停止监测系统工作。

五、两台泵互换运转

1、备用泵空载运转正常后,调小运转泵的流量。

2、开启备用泵与运转泵系统间的联络阀,并关闭备用泵的配风门,使备用泵低负荷与运转泵并联运转。

3、当备用泵带负荷运转正常后,停止原抽放泵运转,并开、关有关阀门,调整备用泵的流量。

篇2:通风各工种操作规程

1、瓦斯检查员负责检查所管辖范围内的瓦斯浓度、温度及“一通三防”设施的运行情况。

2、必须熟悉矿井通风系统和所管辖范围内的通风、瓦斯、防尘、防灭火设施。

3、必须严格执行《煤矿安全规程》及其它有关通风、瓦斯等的规定,会填写瓦斯检查记录手册、牌板及有关报表。

4、当井下局部地区瓦斯超限时,在浓度小于3%时,能及时处理;发现“一通三防”中的隐患时,能立即采取措施,并应向通风调度汇报。

5、应严格执行交接班制度。

二、操作前的准备工作

1、瓦斯检查员应携带瓦检仪、检查棍、胶皮管、温度计、记录表格,如有自然发火煤层还应携带一氧化碳检定器。

2、在领取瓦检仪时应检查药品、电路、气密性、条纹是否符合要求;领取一氧化碳检定器时应检查气密性和螺栓。

三、检查瓦斯操作

1、使用瓦斯检定器,检查甲烷和二氧化碳浓度的方法如下:

(1)在待测瓦斯地点的进风流中清洗瓦斯气室,将微读数回零位,基线对零。(2)在检测地点、带辅助管挤压气泵5~7次,观测检定器,读出甲烷浓度。(3)在检测地点检查二氧化碳浓度时,先按上述方法测出甲烷浓度,再将辅助管拔掉,用检查甲烷的方法测出混合气体浓度;混合气体浓度减去甲烷浓度即得二氧化碳浓度。

2、需要测定瓦斯的地点如下:

(1)采煤工作面测定甲烷和二氧化碳的地点有:

①工作面进风流(指进风顺槽至工作面煤壁线以外的风流);

②工作面风流(指距煤壁、顶、底板各20厘米和以老塘侧切顶线为界空间风流); ③上隅角(指采煤工作面回风侧最后一架棚落后侧1米处);

④工作面回风流(指距采煤工作面10米以外的回风顺槽内不与其它风流汇合的一段风流); ⑤尾巷(指高瓦斯与瓦斯突出矿井采煤工作面专用于排放瓦斯的巷道)栅栏处。(2)掘进工作面需测定甲烷及二氧化碳的地点有:

①掘进工作面风流(指风筒出口或入口前方到掘进工作面的一段风流); ②掘进工作面回风流;

③局部通风机前后各10米以内的风流; ④局部高冒区域。

(3)矿井总回风或一翼回风流中的甲烷和二氧化碳的测定在各测风站内进行。(4)采区回风流中的甲烷和二氧化碳的测定在该采区各分区风流汇合后的测风站内进行。

(5)硐室的甲烷、二氧化碳及其他有害气体的测定在各硐室内进行。

(6)设置有电动机(如小绞车、水泵采煤机、掘进机、移动变电所等)的采掘工作面进风流中的甲烷和二氧化碳的检查应在以电动机为中心的进回风两端各20米范围内的巷道内进行。

3、放炮地点检查瓦斯的部位有:

(1)采煤工作面放炮地点的瓦斯检查应在沿工作面煤壁上下各20米范围内的风流中进行;

(2)掘进工作面放炮地点的瓦斯检查应在该点向外20米范围内的巷道风流中及本范围内局部瓦斯积聚处进行。

4、循环检查瓦斯的次数和顺序是:

(1)瓦斯检查次数按《煤矿安全规程》的有关规定执行。(2)循环检查瓦斯的顺序和有关规定如下:

①采煤工作面是从进风巷开始,经采煤工作面、上隅角、回风巷、尾巷栅栏处等为一次循环检查;

②双巷掘进工作面由一名瓦斯检查员检查时,一次循环检查瓦斯应从进风侧掘进面开始到回风侧掘进面;

③循环检查中同,应在采掘工作面上、下检查的间隔时间里确定无人工作区或其他检查点的检查时间;

④采掘工作面检查瓦斯的间隔时间要均匀,在正常情况下,每班检查3次的,其相隔时间不允许过大或过小。每班检查2次的,其相隔时间要求不允许半班内完成一班的检查 2 次数。

(3)每次检查瓦斯后,必须填写瓦斯记录手册、黑板牌,并随时向调度站汇报。(4)局部瓦斯积聚或临时停风的盲巷内积聚瓦斯时,在瓦斯浓度不超过3%的情况下,可按照制定的排放措施就地排放。当积聚的瓦斯浓度超过3%时,应报请矿总工程师主持制定措施,并按措施规定进行排放。

(5)瓦斯检查记录牌板的吊挂位置,对于回采工作面应挂在进、回风巷的顶板良好处,有尾巷的挂在栅栏处;对于临时停工的掘进工作面、已采区、火区密闭墙、盲巷、硐室等应挂在顶板良好的栅栏处。

(6)瓦斯检查牌板填写内容包括检查地点名称、甲烷及二氧化碳浓度、其它有害气体浓度、温度、检查日期、班次、时间、次数、瓦斯检查员姓名等。瓦斯检查记录牌板应随着检查地点位置的变化而及时移动。

(7)每班应对管辖范围内的传感器的数据进行校对和记录、对监测装置及电缆的外观进行检查,并将记录和检查结果报通风调度和监测值班员。

(8)每个地区的瓦斯检查员和专职瓦斯检查员在发现本区域内“一通三防”方面有异常情况时,应立即采取措施,并将情况向通风调度汇报。

(9)瓦斯检查员必须严格执行现场交接班制度。

四、特殊地点检查瓦斯的操作

1、高瓦斯及煤与瓦斯突出矿井中使用采煤机和掘进机的采掘工作面的跟机瓦斯检查员,必须坚守岗位。当采煤机、掘进机工作时,在以下地点检查瓦斯:

(1)检查采煤机前后20米内,距煤壁30厘米、距顶板20厘米范围内的瓦斯。当局部积聚的瓦斯浓度达2%或采煤机前后20米内风流中瓦斯浓度达1.5%时,应停止采煤机工作,切断工作面电源,立即进行处理。

(2)利用检查棍、胶皮管检查采煤机滚筒之间、距煤壁30厘米、距顶板20厘米范围内的瓦斯。当瓦斯浓度达2%时,应停止采煤机的工作,切断工作面电源,进行处理;凡处理不了的应立即向通风调度汇报。

(3)对于使用掘进机的掘进工作面,当掘进机工作时,应检查掘进机的电动机附近20米范围内及风筒出口至煤壁间风流中的瓦斯浓度。当瓦斯浓度达到1.5%或掘进工作回风流中瓦斯浓度达到1%时,应停止掘进机工作,切断工作面电源,立即进行处理;处理不了的应向通风调度汇报。

2、煤仓内的瓦斯检查及煤仓堵塞后的瓦斯检查与处理,应按矿总工程师组织编制的措施进行。

3、高瓦斯矿井和煤与瓦斯突出矿井采掘工作面的专职瓦斯检查员应认真执行“一炮三检”制度,瓦斯检查员不在现场不准放炮。

4、对于高瓦斯矿井和煤与瓦斯突出矿井的采掘 工作面,瓦斯检查员应定点检查瓦斯和其它有害气体及温度等。需进行定点检查的地点包括采煤工作面采空区边缘、工作面风流、工作面上隅角、工作面刮板输送机及溜子尾附近和底部、局部漏顶处、高冒处,掘进工作面迎头、巷道全长风流、局部高冒处、漏顶处、局部通风机附近等。发现超限应立即停止工作,切断电源,进行处理;处理不了的,应向通风调度汇报。

5、采煤工作面采空区放炮放顶时,采空区瓦斯浓度的检查范围应按矿总工程师组织编制的措施中的有关规定执行,当瓦斯浓度超限时,应立即停止放炮。

五、操作中的注意事项

1、检查瓦斯时,应按照以下操作顺序进行,并注意自身安全。

2、检查高冒地点、采煤工作面上隅角、采空区边缘的瓦斯时,要站在支护完好的地点用小棍将胶管送到检测地点,由低到高逐渐向上检查,检查人员的头部切忌超越检查的最大高度,以防缺氧而窒息。

3、检查废巷、盲巷和临时停风的掘进工作面及密闭墙外的瓦斯、二氧化碳及其它有害气体时,只淮在栅栏处检查;必须进入盲洞内检查时,应由救护队员进行。

4、携带的瓦斯检定器要妥善保护好同,不准碰撞损坏、丢失及转借他人;出现故障不准擅自修理,应上井后交检修人员并指出存在的问题;瓦斯检定器不得个人保存,上井后应交仪器房保管。

5、排放局部积聚的瓦斯之前,应按有关规定将本区域回风系统中的人员全部撤入进风流中,切断电源。

放炮员操作规程 一、一般规定

第1条 采煤工作面放炮员必须由责任心强,具有二年以上采煤经验,熟悉通风、瓦 4 斯和爆破材料管理及放炮技术,经过培训、考试合格,持有放炮员合格证的专职人员担任。

第2条 严格遵守《煤矿安全规程》有关通风、瓦斯、火药管理等规定,切实执行工作面作业规程及其爆破说明书和本操作规程。

第3条 严格执行“一炮三检”制度。工作面放炮前,放炮员、班组长、瓦斯检查员和兼职安监员都应在现场。

第4条 在有瓦斯或煤尘爆炸危险的煤层中放炮时,必须采用正向爆破,严禁反向爆破。

第5条 严禁采用糊炮、明火、普通导爆索或非电导爆管放炮。

第6条 放炮与回采其它工序平行作业时,必须按照放炮的安全距离规定执行,否则应停止放炮。

第7条 在地质变化地带、冒顶区、安全出口等处的顶板破碎、煤层松软、容易冒顶片帮的地段,要少装药放小炮或不放炮。

第8条 放炮员要和打眼工密切配合,保证爆破时不崩倒棚子、不丢顶煤和底煤、不将煤块大量崩溅空巷,保证煤壁平直,符合开帮进度要求。

第9条 运送爆破材料和封泥装药可由兼职的放炮员助手进行。放炮员助手必须经过培训并考试合格,取得合格证后,方可操作。

1、在井下火药库领取火药和雷管时,要根据本班生产情况领取火药、雷管当面点清数量,认真检查火药雷管质量品种,然后盖章。

2、领取的火药雷管要分别放入不同的箱中并加锁。

3、放炮员本人如拿不完所领取的全部火药雷管,应由当班班长指派专人帮助运送,但雷管必须由放炮员本人携带,中途行走时前后两个要错开一定距离,严禁并排行走,中途休息要选择安全地点。背送火药雷管时不准乘坐车辆和皮带。

4、火药雷管运送到工作地点后,必须放在支架完好、避开机械电器设备的安全地点。第10条 放炮员的工作顺序:

准备(领取工具和爆破材料→运送爆破材料→存放爆破材料→装配引药)→检查处理→放炮操作(装药→高警戒→联线→放炮→炮后检验→撤警戒)→收尾工作。

第11条 装药前,放炮员要与班组长及瓦斯检查员对工作面及炮眼进行全面检查,对所检查出的问题,应及时处理。在有下列情况之一时,不准进行装药。

1、装药地点20米以内风流中,瓦斯浓度达到1%时;

2、工作面风量不足或风向不稳定;

3、装药地点20米以内煤尘堆集飞扬;

4、装药地点有片帮冒顶的危险;

5、有伞檐,炮道不符合规定,煤壁局部突出0.3米以上;

6、炮眼内有异状,有压力水、瓦斯突增、炮眼塌陷出现裂缝,温度骤高骤低等;

7、有眼深小于0.6米的炮眼或不符合规程规定的眼深、位置、方向等;

8、炮眼内煤粉未清除干净;

9、基本支护与特种支护不齐全,支护有损坏未处理;

10、发现瞎炮未处理。

二、放炮操作 第12条 装药

1、从成束的雷管中抽取单个雷管时,不得用手拉脚线硬拽雷管体,也不得用手拉管体硬拽脚线,应将成束的雷管脚线顺好,拉住前端脚线管体抽出。

2、装配引药时,必须严格遵守以下规定:

装配引药必须在顶板完好、支架完整、避开电器设备和导体的放炮地点附近进行,禁止做在火药箱上装配引药。装配引药的数量,以当时当地需要的数量为限。

装配引药时,必须防止电雷管受震动或冲击以及折断雷管脚线和损坏脚线绝缘层。电雷管只许由药卷的顶部装入,不得用电雷管代替竹、木棍扎眼。电雷管必须全部插入药卷内。禁止将电雷管斜插在药卷的中部或捆在药卷上。

电雷管插入药卷后,应用脚线将药卷缠住,以便把电雷管固定在药卷内,还必须将电雷管脚线手端扭结。

在装配引药地点只允许放炮员一个人在此操作,非装配引药人员不得靠近。装配好的炮头要整齐的放在药箱内,并且点清数目,不得丢失。

3、装药时,首先用炮棍将炮眼内的煤粉或岩粉清除干净,用炮棍探明角度和深度后,再用跑棍将炮头和随装药轻轻地分次推入炮眼内。各药卷必须彼此密接,推进火药时,不得猛力冲撞。

4、潮湿或有水的炮眼,应用抗水炸药或用防水套。

5、正向爆破的引药最后装,装引药时其聚能端应朝向眼底,6、炮眼封泥应采用水炮泥。装填水炮泥时应先紧靠药卷填上0.03~0.04米的炮泥,6 然后装水炮泥,外端再填以炮泥。注意不要用力过猛和压的太紧,以防捣破水炮泥。不得使用漏水的水炮泥;

7、封泥应用不燃性的砂、粘土、禁止使用块状材料或可燃性材料。

8、对有水的俯角炮眼装药,应采用串联的方法把一定数量的药卷装入防水套里系好口,一次送入炮眼内。

9、装完药后,应先将跑泥先装入而后装水炮泥,最后用炮泥封严。装炮泥时要一节一节装,第一二节要慢用力,轻捣动,以后炮泥可依次一一用力捣。

10、捣炮泥时须用手拉住雷管角线,要拉直,但不要拉紧,脚线紧贴在炮眼下壁,或侧壁、防止捣坏。

11、封完炮泥后,要将角线联结、悬挂起来,以防与轨道、金属管子、钢丝绳、刮板输送机等导电体接触,发生误爆现象。

第12条 炮眼深度和封泥量的规定:

1、炮眼深度小于0.6米时,不准装药放炮;

2、炮眼深度为0.6米至1米时,封泥长度不得小于炮眼深度的二分之一;

3、炮眼长度超过1米时,封泥长度不得小于0.5米。第13条 设警戒。

1、联线前,班组长必须亲自布置专人在警戒线和可能进入放炮地点的所有通路上担任警戒,放炮员须为警戒人员之一;

2、警戒线必须设在顶板、支架完好的地点,并要设置警戒牌、栏杆或拉绳等标志;

3、放炮时,所有人员都应在警戒线之外;

4、工作面若与其它采掘面贯通,在相距15米时,必须在要贯通处设警戒,直至贯通。贯通处两头都要在放炮前检查瓦斯;

5、警戒的安全距离应符合集团公司、矿的规定。第14条 检查及处理。

在联线和放炮前,放炮员要和班组长、瓦斯检查员对放炮的地点进行第二次检查,对查出的问题应及时处理。

第15条 联线。

1、要按照作业规程规定的放炮顺序和联线方法联线放炮;

2、严格执行谁联线谁放炮,即放炮母线联电雷管脚线及检查线路和通电都必须由放炮 7 员本人操作;

3、工作面布置的单排眼、双排眼、三花眼或五星眼的联线都采用大串联法,最后剩下的两条脚线在未和线线联结前要扭结成短路; 母线未和脚线联结前,两端必须扭结成短路。

4、母线与脚线联结后,再沿路检查母线。放炮员应最后退出放炮地点。第16条 放炮。

1、母线与电雷管脚线联结后,放炮员即吹第一次口哨并大声叫喊“要放炮啦”;

2、放炮员沿路检查路线,第二次吹口哨并大声叫喊:“快放炮啦”;

3、到达放炮的警戒地点后,将母线联接在放炮器的接线端并拧紧,这时第三次吹口哨并大声叫喊“放炮啦”,等待30秒后,用钥匙将开关转到充电位置,待氖灯闪亮稳定,将开关钥匙转到原来放电位置起爆;

4、炮响后,首先取下放炮器钥匙,然后将母线从放炮器上摘下并打结短路。第17条 处理瞎炮时,必须遵守下列规定:

1、在距瞎炮至少0.3米处另打同瞎炮眼平行的新炮眼,重新装药放炮;

2、严禁用镐刨或从炮眼中取出原放置的引药或从引药中拉出电雷管;严禁将炮眼残底(无论有无引余炸药)继续加深;严禁用打眼的方法往外掏药;严禁用压风吹这些炮眼;

3、处理瞎炮的炮眼爆炸后,放炮员必须详细检查炸落的煤、矸,收集未爆的电雷管;

4、在瞎炮处理完毕以前,严禁在该地点进行同处理瞎炮无关的工作。

第18条 装药的炮眼必须当班放炮完毕。若遇特殊情况无法当班放完时,必须在现场向下班放炮员交清情况。

第19条 在本班放完炮、吹散炮烟并经班组长同意后,放炮员须吹长哨并大声喊“放完炮啦”,方可撤警戒和让其他人员进入工作面作业。

通风保安工操作规程

风筒施工 一、一般规定

风筒工负责所管辖区域内风筒的安装、运送、维修和拆除等工作。及时将不用或损坏 8 的风筒回收上井,并及时修补井上下破损的风筒。

二、井下风筒的安装、拆除和维修

1、入井必须带足必要的用具和材料,必须熟悉自己分管地区掘进工作面情况,如风筒直径、长度、巷道掘进速度或贯通日期等。

2、风筒吊挂要平直、紧、稳、避免车刮、炮崩,必须逢环必挂。铁风筒每节吊挂两点,每节风筒末端两侧的挂钩应用铁丝系在巷道帮壁上。

3、要求风筒之间接口严密。胶质风筒可用双反边接头或三环接头,插接时要顺接。

4、使用胶质风筒时,局部通风机和胶质风筒之间要有一节铁风筒过渡。局部通风机和胶质风筒的接头处要加垫圈,要上紧螺丝;铁风筒和胶质风筒套接处要用铁丝箍紧。

5、一列风筒的直径要一致;如果直径不一,要有过渡节。

6、风筒末端距工作面的距离,按各集团公司的规定执行,但保证工作面有足够的风量。

7、经常检查井下风筒,如有破口要随时修补,做到不漏风。

8、风筒在拐弯处要设弯头或缓慢拐弯,不准拐死弯。分岔处要设三通。

9、斜巷和立井掘进时,风筒接头、风筒的帮扎要特别牢固。

10、更换风筒时,不得随意停局部通风机;必须停机时,应与掘进工作面的班组长和司机联系,待停止工作、撤出人员后方可更换。当巷道内瓦斯涌出量大时,必须把工作面人员撤到安全地点后更换风筒。

11、巷道掘进完工后,应在通风区的指挥下及时把风筒全部拆除。拆除的风筒要装车运至井上,进行冲洗、晒干和修补。

12、拆除风筒时,应由里向外依次拆除。拆除独头巷道风筒时,不准停局部通风机。

三、安装、拆除风筒时的注意事项

1、应注意防止运行中的矿车撞、挤、刮风筒。

2、跨带式输送机、刮板输送机操作时,必须先同输送机司机联系好,必要时可暂停输送机运转,以保证操作安全。

3、大巷高钉操作时要设台架,工作时要站稳;在电机车运行的巷道中吊挂风筒时,要设安全警戒,严防被电车刮、撞,并注意防止架空线触电伤人。

四、采用抽出式通风方式操作时的注意事项

1、采用抽出式通风方式时,风筒可用硬质风筒和带钢丝骨架的橡胶或塑料可伸缩风筒。橡胶或塑料风筒必须具有抗静电和阻燃的安全性能。

2、安装钢丝骨架风筒时,在装卸过程中应注意轻装轻放,且勿径向挤压和被锋利杂物碰撞等,以免变形损坏。

3、用快速接头软带连接风筒时,两节风筒的端圈要对正、接拢、披风布搭好后,再用快速接头软带将两端圈卡紧。接头软带收紧力要适当,以不漏风、不拉脱为宜,接头软带的手把位置以在风筒侧面向下为好。

4、在风筒末端(入风口)加接风筒时,应先将加接的风筒吊挂于钢丝绞线上,再对正接头接好,避免风筒弯曲、折叠堵塞风道。

5、风筒急拐弯处必须用硬质弧形弯头连接。

6、处理风筒内的积水时,在风筒长度超过500米时,可以直接解开快速接头软带进行放水;在处理500米以内的风筒的积水时,须先打开局部通风机安全窗,然后方能解开接头进行放水。

7、采用抽出式或混合式通风方式时,风筒出口或入口到工作面的距离、压入式风筒和抽出式风筒间重叠段长度,应符合各矿作业规程的规定。

五、地面修补风筒

1、风筒上井后,首先应刷洗、晒干,检查风筒损坏情况及耐用程度,再根据检查情况分别处理。

2、修补风筒时,沾补风筒的胶浆应按要求配制。根据破口大小裁剪补钉,补钉以圆形为好;补钉压边应大于破口尺寸20毫米;为防止补钉补后翘边,补钉边应裁成斜面;补钉和破口应刷净至露出胶质风筒本色,晾干后才能涂上胶浆进行沾合,补钉沾合后应用木手锤砸实,使其沾合严密,保证不漏风;沾好的风筒应再涂上滑石粉。对100毫米以上的大破口,必须先用线缝合后再进行粘补。

3、风筒上的吊环应齐全,吊环间距应保持风筒吊挂平直,两端铁圈要缝牢。如果需要加长风筒时,风筒之间压边粘合的宽度一般为200毫米。

4、修补好的风筒应妥善保存,存放的风筒每季度应晾晒一次。

5、制作三通、弯头及过度节时,要根据风筒的形状和直径制作,要注意平直。过度节长度不应少于2米。

6、焊接风筒圈时,要按电焊工的有关规定进行。圈要焊牢固,并要焊平调圆。

7、晾晒、冲洗、清扫风筒时要戴口罩,风筒必须在晾干或吹干后方能粘补。

8、修补后的旧风筒,应按照规格尺寸分别存放在指定地点,并做好标志,以取用方便。

9、装卸风筒时应注意安全,要防止铁丝划收、扎脚和碰伤眼睛。

六、地面修补风筒时的注意事项

1、修补风筒时应准备一台局部通风机,用来吹干风筒,并准备一台缝纫机及修理工具。

2、汽油、胶水必须存放在单独房间内,并应保持油桶严密,严禁烟火。

3、风筒修理室内禁止使用火炉取暖;若必须使用时,应有安全防火措施,并经有关单位批准,下班无人时应将火炉熄灭。

4、风筒修理室内必须备有灭火器材,做好防灭火工作,室内要保持清洁卫生。

5、电动缝纫机的操作既注意事项如下:

(1)电动缝纫机必须安装合格、绝缘良好,防止漏电伤人。

(2)缝纫机使用者必须经过培训,在熟练掌握机器性能后才能独立操作。(3)使用缝纫机前,应先检查各部件是否完好,转动是否灵活。(4)使用前各油烟都要适当注油,使用中要随时加油。

(5)使用缝纫机时,不宜戴手套,两手距离机针必须在60毫米以上。上下线要均匀,要掌握一定转速,防止扎手。

(6)使用中如出现故障,应立即停机处理,故障排除后再用。(7)修理中需拆卸机头时,注意不要丢失零件。

(8)交接班时,应把机器擦净;发生故障本班处理不完时,要详细向下一班交待清楚,以便继续处理。

6、洗风筒机的操作使用及注意事项如下:

(1)要由专人负责,操作人员首先要掌握操作方法。

(2)工作前,应首先检查机器的完好状况,然后才允许操作和合闸送电。

(3)操作人员必须穿胶鞋、戴绝缘手套和戴工作帽,衣服穿戴要整齐,以防触电和衣物被卷入机器。

(4)开始工作时,首先将离合手把打到控制位(即工作状态),并打紧。

(5)开外壳时,应两手端平,向上推起。如果再开其外壳后,内壳位置不当,要用手摇动涡轮装置,使内壳转动到合适位置,不得用手直接转动内壳。

(6)内壳开启后,再开始加水,加水要适量,一般为整机的五分之二较为适当。加水后将所要洗的风筒加入机内,一般洗直径为500~600毫米风筒时放一节,500毫米以下的风筒放2节。

11(7)放入风筒后,先盖内壳,内壳一定要拧紧、盖严,防止风筒和水被甩出而发生意外,内壳盖好后再盖外壳,也要拧紧盖好。

(8)盖好内壳后,将离合手把打到松开位置,即“0”位上。

(9)确认可以开机时,由专人负责送电,送电人员必须戴干燥绝缘手套才能合闸送电。先送电、后开机,在开机时,所有人员应远离机器。

(10)洗10~15分钟后即可停电。停转平稳后,操作人员才可靠近机器,此时严禁送电。

(11)操作人员按顺序区楚风筒并按动放水装置排出脏水,另换净水。

密闭施工

一、准备工作

1、装运材料要由专人负责。各种材料装车后均不能超过矿车高度、宽度,装车要整齐,两头要均衡。

2、料车入井前必须与矿井调度室及有关单位联系,运送时应严格遵照运输部门的有关规定。

3、施工人员随身携带的小型材料和工具要拿稳,利刃工具要装入护套,材料应捆扎牢固。要防止触碰架空线。

4、井下装卸笨重材料时要互相照应,靠巷帮堆放的材料要整齐,不得影响运输、通风、行人。

5、人力运料过煤眼时,要注意安全,不准用刮板输送机及带式输送机运送材料。

6、施工前必须对施工地点、规格、要求了解清楚,并掌握有关安全技术措施和施工要求,做到安全施工。

7、密闭位置应选择在顶帮坚硬、未遭破坏的煤岩巷道内,尽量避免设在动压区。

8、施工地点必须通风良好,瓦斯、二氧化碳等有害气体的浓度不超过《煤矿安全规程》的规定时方可施工。

9、必须由里向外逐步检查施工地点前后5米的支架、顶板情况,并且由一人处理、一人监护,处理不完必须及时打上临时支柱。

10、拆除密闭地点支架时,必须先加固其附近巷道支架;若顶板破碎,应先用托棚或探梁将梁托住,再拆除棚腿,不准空顶作业。

11、掏槽时应注意以下几点:

(1)掏槽一般应按先上后下的原则进行,掏出的煤、矸等物要及时运走,巷道应清理干净。

(2)掏槽深度必须符合规定要求,见实帮实底。

(3)砌碹巷道密闭要拆碹掏槽,并按专门安全措施施工。

二、永久密闭施工操作

1、在有水沟的巷道中砌墙时,既应保持水流畅通又不能漏风。

2、用砖、料石砌墙时,竖缝要错开,横缝要水平,排列必须整齐;砂浆要饱满,灰缝要均匀一致;干砖要浸湿;墙心逐层用砂浆填实;墙厚要符合标准。

3、双层砖或料石墙中间填黄土的密闭,黄土湿度不宜大,且应随砌随填,层层用木棰捣实。

4、砌墙到中上部时要预留观测孔及灌浆孔,铁管孔口应深入密闭墙内1米以上,外口距密闭墙至少0.2米,外口要设阀门,不用时关闭。

5、密闭封顶要与顶帮接实。当顶板破碎时,托棚或探梁上的原支架棚梁应随砌墙进度而逐渐拆下,且应除去浮煤、矸后再掏槽砌墙。

6、密闭墙砌实后要勾缝或抹面,墙四周要包边抹,其宽度不少于0.2米。要求抹平,打光压实。

三、临时密闭施工操作

1、用砖建筑的临时密闭的厚度不应小于240毫米,其他质量要求与永久密闭相同。

2、建筑木板临时密闭时应满足以下要求:

3、应根据巷道断面大小,确定打立柱的数量,立柱要打牢固,且与巷道顶底板接实。

4、木板条采用鱼鳞式搭接方式。自上往下一次压茬排列钉在立柱上,压茬宽度不少于15毫米,在四周木板均要伸入槽内接实。

5、木板钉严实后,必须清除杂物,然后用白石灰加黄泥或水泥加黄泥桨沿木板压茬缝及墙四周堵抹平整严密。

四、密闭施工中的注意事项

1、掏槽时只能用大锤、钎子、手镐、风镐施工,不准采用放炮方法。

2、在立眼或急倾斜巷道中施工时,必须配戴保险带,并制定安全措施。

3、砌墙高度超过2米时,要搭脚手架,保证安全牢靠。

4、施工完毕后,要认真清理现场,做到密闭前5米支架完好,在距巷道岔口1~2米处应设置栅栏,揭示警标,悬挂说明牌。

风门施工

一、施工前的准备工作

1、装运材料及施工前的准备工作与施工密闭时的相同。

2、在有电缆线、管路处施工时,要妥善保护电缆、管路,防止碰坏。

3、需移动高压电缆时,要事先与机电部门取得联系。

4、墙垛四周要掏槽,其深度必须符合质量要求。

二、永久风门施工操作

1、稳门框时应按以下规定进行:

(1)先稳下门坎,下坎的上水平面要稍高于轨面,下坎设好后再安装门框及上坎横梁,要求门框与门坎互成直角,上下坎应互相平行。

(2)根据风压大小,门框应朝顺风方向倾斜一定角度,一般以85度左右为宜。调好门框倾角后,用棍棒、铁丝将门框稳固。

2、在有水沟的巷道中砌风门墙垛前,必须先砌反水池;砌墙垛时应按永久密闭施工操作要求施工;两边墙垛施工要平行进行,逐渐把门框牢固嵌入墙垛内。

3、若需要在风门墙垛中通过电缆线路时,在砌墙时要预留孔口孔位。

4、反向风门要与正向风门同时施工,除门框倾斜角度、开关方向与正向风门相反外,其余要求与正向风门相同。

5、风门墙垛砌好后,墙两边均要用细灰砂浆勾缝或满抹平整,做到不漏风。水泥砂浆凝固后,方可挂风门扇。

6、安装门轴时,应将做好的门轴带螺丝的一端打入在门框上钻取的孔内,并打正装牢。

7、安装门扇时,应将门带上的圆孔套入门框的轴上,并使门扇四周接触严密,要求风门不坠、不歪,开关灵活。

8、风门下部及水沟处应钉挡风帘,确保严密不漏风;管线空应用黄泥封堵严实。

9、安设有自动开关装置的主要通车风门时,应保证其灵敏可靠、开关灵活。

三、临时木板风门的安设操作

1、立柱安装要牢固,且要留设一定倾角;回风侧要打撑木,风压大时回风侧门上坎过梁上要设横梁,并牢固嵌入巷道两帮。稳门框操作与第28条相同。

2、稳框后钉木板时,上下木板之间要求采用鱼鳞式搭接,且应由上往下钉,其压茬宽度不得小于20毫米,顶帮及下帮要压边并接触槽内实茬。

3、木板钉齐后要清渣抹缝,杂物要清除干净,并用黄泥掺水泥或白灰浆勾缝或满抹,保证墙面、四周不漏风。

4、水泥浆凝固后即可安装风门扇,门扇的安装及调整与永久风门相同。

四、调节风窗安装操作

1、密闭墙上需设调节风窗时,窗框预留在墙的正上方;风门上设有调节风窗时,窗框预留在风门扇的上方。

2、当密闭、风门墙砌筑到预留位置时,即可将预制好的调节风窗框嵌入墙内。调解窗口要备有可调节的插板。

3、调解风窗除窗口施工外,其余质量标准和施工操作要求与风门、密闭的质量标准和施工操作相同。

五、风门施工安全注意事项

1、在架线巷道中设风门及进行有关工作时,必须先和有关单位联系,在停电、挂好“有人工作,不准送电”的停电牌、设好临时地线及保护好架线后方能施工。施工完毕后即取下临时地线,在下停电牌,合闸送电。

2、在运输巷道中设风门时,要注意来往车辆,做到安全施工。

3、每个风门施工完毕后,其前后5米内的支架要保证完好,并清理剩余材料,保持清洁、畅通。

测风站施工

一、施工前准备工作

1、测风站选点要符合《煤矿安全规程》的有关规定。

2、施工地点的巷道高度超过2米时,要搭脚手架,做到安全施工。

二、施工操作

1、在砌碹或锚喷巷道中建测风站巷帮凹凸变化大时,应首先用喷浆方法或用水泥砂浆将凹凸补平;再用和匀的西黄沙掺水泥、白灰掺麻刀将巷道顶、帮平抹;进、出风侧巷壁应平滑,抹面长度不少4米。

2、在架木棚巷道中建测风站时,应首先加固巷道支架;再用木板逐块排列钉在巷道顶帮支架上,要求钉牢且平整;进、出风侧钉成后应平滑。

3、在水泥棚、铁轨棚巷道中建测风站时,要先用小方木固定在棚档中作衬料,然后用木板平整排列钉在方木上。

4、测风站内有水沟时,水沟上必须加盖板,并密闭严实,其前后长度不小于10米。测风站两端水沟内要设挡风帘。

5、测风站施工完毕后,站内必须设测风瓦斯记录板。

6、施工完毕后必须清理测风站前后10米内的杂物,保持巷道清洁畅通。

7、在架线巷道中施工时,要事先制订专门的停送电安全措施,并按措施施工。

风桥施工

一、施工前的准备工作

1、施工前,必须掌握施工图纸要求和安全技术措施,并按要求施工。

2、施工地点要进行通风,并检查瓦斯、二氧化碳等情况,保证施工安全。

3、准备好施工所需材料及工具,妥善保护施工地点敷设的管路、电缆等设备,并检查巷道支护情况,发现问题及时处理。

二、风桥施工操作

1、两坡挑顶的要求如下:

(1)挑顶前先加固顶板及其坡点外5米内的支架。(2)根据施工要求打炮眼,放炮挑顶。

(3)装药、放炮必须由专职放炮员按有关规定进行。放炮前必须撤出人员,在巷道交叉口外设好警戒,发出信号后再放炮。

(4)放炮后由施工负责人和放炮员共同验炮。验炮后应一人监护,并打上临时支柱后再清渣。

2、挑正顶的要求如下:

(1)挑正顶前,先将炮眼打好,然后回掉原支架;装药时,必须认真检查顶板,并打好临时支柱;放炮只能放小炮。

(2)挑正顶时必须先加强下巷支架,必要时可在棚梁下打临时支柱。

3、卧底时,应先在附近支架棚梁处打上临时支柱,维护好顶板。

4、对砌墙的要求如下:

(1)可用砖、料石砌墙,风桥两端坡度不能大于30度,应成流线型。(2)砌墙应先放好中腰线,并按规定掏槽,应见实帮实底。

(3)墙面要砌平整,勾缝或抹面应符合质量标准要求,顶帮迎接严填实。

(4)风桥前墙及桥面用水泥预制板铺密,后墙用砖或料石砌筑,墙中加填黄土,层层用木棰捣实,应用砂浆将桥面抹平。

5、上巷支护需要支棚打柱时,必须穿鞋;正顶要打在下巷棚梁上;坡巷的支架必须牢固,起坡处棚柱要与巷道顶部垂直。

6、服务年限短,风量小于10m3/s时,可采用铁桶式风桥。

7、风桥施工完毕后,要将管路、电缆悬挂整齐,现场清理干净。

三、风桥施工时的注意事项

1、用铁桶作风桥时,每个接头均要加衬垫、拧紧,两端应成流线型。

2、施工时,现场负责人要经常检查支架顶板情况,发现问题及时处理,并将人员撤到安全地点,然后向通风区调度汇报。

3、风桥中不准设风门,上、下巷连通的绕道需设风门时,按风门施工的要求进行。

4、风桥建成后,要将内外墙全面整修勾缝或抹面。竣工后,报通风区验收,凡不符合质量标准处,必须返工。

冲尘工操作规程

1、洗尘工必须持证上岗。

2、洗尘工必须能够看懂矿井清水系统图。

3、洗尘工洗尘时必须将洗尘所使用的胶管、接头等携带齐全。

4、洗尘工洗尘时必须佩戴风镜、防尘口罩,防止粉尘飞溅入眼、口中。

5、仔细检查巷道顶板支护情况,发现隐患必须及时处理,必须在确保安全的前提下方可施工。

6、冲洗巷道必须认真、仔细、不留死角,务必将巷道冲洗干净。

7、冲洗巷道时应将开关等电气设施用风筒布或其它物件将其遮盖,防止受潮。

8、冼尘所用过的水管堵头,必须拧紧,不得漏洗。洗尘时,有跑水的管子必须进行处理。

9、洗尘结束后,要将洗尘所用的工具及时回收上井,严禁在井下乱扔乱放。

测风员操作规程 一、一般规定

第1条 测风员应担负以下工作:

1、测算矿井风量、风压、漏风量,按计划要求进行风量调节。

2、测定局部通风机的风量、风压和漏风量。

3、在鉴定矿井瓦斯等级、进行矿井反风试验、测定主要通风机性能时,测定有关参数和汇总资料。

4、及时准确填写有关报表和井下测风牌板。

第2条 必须熟悉矿井通风系统,严格执行《煤矿安全规程》,发现问题及时向通风调度汇报。

二、测风前的准备工作

第3条 入井前应对所用的仪表进行检查,并符合以下要求:

1、风表开关、回零装置和指针灵活可靠,外壳及各部位螺丝无松动、风表校正曲线对号。

2、秒表的开关和指针灵活。

3、入井前必须根据任务带好所用的风表、秒表、瓦斯鉴定器及皮尺、记录本、有关仪器等。携带和使用仪器时,必须轻拿轻放,避免碰撞。第4条 井下测风地点的选择:

1、测风地点应选择在:矿井、一翼、水平的进回风巷,采区进回风巷,采掘工作面进回风巷,井下爆破材料库和主要用风硐室,以及其它需要用风的地点。

2、主要风道中的测风工作应在测风站内进行。

3、在无测风站的地点测风时,应选在巷道断面规整、支护良好、无空顶片帮、前后10米巷道内无障碍物和拐弯的地点。

第5条 根据测量风速的大小,选用合适的风表。测风具体操作为:

1、测风时,必须风表、秒表同时打开,测风时间为1分钟。

2、每一测风地点的测量次数应不低于三次。三次测量误差不超过3%,如果误差太大时,应重新测量。

3、测风时,测风员要用测身法进行测量。具体作法:侧身站在巷道内,背向巷道壁站立,手持风表将手臂向风流垂直方向伸出,风表度盘那一面背向风流,然后在巷道中均匀移动。

测尘工操作规程 一、一般规定

测尘工应能作用仪表测定粉尘浓度,并提出控制粉尘的措施意见。

二、测尘前准备工作

1、认真检查测尘仪器,做到外表清洁、附件齐全、电键或旋转按钮灵敏可靠。使用光电测尘器时,要检查电池电压,当低于使用电压时,应按要求进行充电。

2、根据该班测尘地点和采样数量准备好使用仪表、工具及其附件。

3、使用粉尘采样器测尘时,要事先认真称量采样滤膜。测量时用塑料镊子取下滤膜两面的夹衬纸,然后将滤膜轻放在分析天平上进行称重,并重量值、编好号码,再放入滤膜盒内,要求滤膜不得有折皱,滤膜盒盖要拧紧,并置于干燥器内;使用光电测尘仪测尘时,要备有足够的滤膜纸带。

4、下井时仪器要随身携带,严禁碰撞、挤压,不得让他人代拿或摆弄。

5、注意观察采样地点顶板、运输等情况,以保证工作中的安全,如有隐患必须首先处 理。

三、测尘注意事项

1、选择测尘位置时应注意以下问题:

(1)、采样地点设在回风侧。

(2)、采取高度在人的呼吸带,一般为1.5米左右。

(3)、在掘进工作面采样时,应在巷道未安装风筒的一侧距装岩(煤)、打眼或喷浆等地点4-5米处进行。

(4)、在机械化采煤工作面采样时,应在采煤机回风侧、距采煤机10-15米处进行。(5)、采煤工作面多工序同时作业时,应在回风巷距工作面回风口10-15米处采样。(6)、在转载点采样时,应在其回风侧转载点3米处进行。

(7)、在其生产尘场所采样时,在不妨碍工人操作的条件下,采样地点应尽量靠近工作作业的呼吸带。

2、测尘时,仪器的采样口必须迎向风流。

3、对测法开始时间的要求是:对于连续性产尘作业,应在生产达到正常状态5分钟后再进行采样;对于间断性产尘作业,应在工人作业时采样。

4、要及时将每次的测尘记录填入台帐。

5、测尘完毕后,要填写粉尘测定结果报告表,月底做好本月粉尘浓度测定报告表,并及时上报。要按照规定定期绘制粉尘浓度曲线图。

6、使用粉尘采们器测尘时,若采样后的滤膜被污染或粉尘失落应作废、重新采样;由于滤膜不耐高温,在55摄氏度以上的采样现场不宜采用。

检定器修理工操作规程 一、一般规定

瓦斯仪器检修工负责瓦斯检定器的检修、校正、电池的更换、药品收发管理工作。

二、检修前的准备工作

第1条 保持室内清洁、明亮、干燥,备有常用工具、仪表、材料以及工作台。第2条 压力表的装置形式可采用垂直形,要求能任意调压、停压不漏气、操作连接方便,易于观测压力的变化情况。

三、仪器的检查

第1条 对收回的光学瓦斯检定器,手压气泵5~6次后,其基线应回零。仪器要擦净,各部件应螺丝齐全、连接牢固可靠、松紧适度,转动部分平稳、柔和,不应有卡壳和急跳现象,并有足够的调整范围。

第2条 对气泵进行检查时,要求在将气泵捏瘪并将胶管折堵后,1分钟内气泵不鼓涨。第3条 用水柱计对气路(不包括药管)进行密封性检查时,要求在将水柱计水柱高度加压到700毫米后,1分钟内水柱不下降。

第4条 电源应开关灵活,仪器条纹清晰。

第5条 仪器精度通过目镜观测,干涉条纹应符合目力定度要求(0%~7%范围内应有5根条纹),不弯曲。

第6条 变色吸收剂的变色部分超过二分之一时,要更换。氯化钙有潮解现象时,要更换。

第7条 检查测微部分时,要求在将基准条纹对准1%,并把小数从“0”调到“1”后,基础条纹应回到零位。

第8条 正常使用的便携式热催化甲烷检测仪,每7天清理一次网上的煤尘,以保持通气性能良好。

第9条 为保证仪器可靠工作,使用前必须进行电压检查。在接通仪器电源5分钟后观察欠压指示或电源指示是否正常,如显示欠压或电池电压不足,要重新充电,电池电压不足时,不准投入使用。

第10条 接通仪器电源开头前,应首先检查电表指示是否在零位,如果不在,应用螺丝刀调整好机械零位。

第11条 电池电压与机械零位合格后方能进行电零位检查,检查时,先接通电源5分钟,然后在新鲜空气中观察机械指示是否在零位,若有差值,可有螺丝刀轻轻调节仪器的零位电位计使用其机械指示为零。

四、光学瓦斯检定器的检修

第1条 对检修的仪器各部分要细致检查,查清故障部位,按检修顺序依电路、光路、气路进行检修。

第2条

拆装螺丝时要用大小合适的螺丝刀,刀尖与螺丝头应垂直。当一个组合件上有几个螺丝时,不可把其中的一个螺丝先拧松、拧紧,而应将对称的各个螺丝均匀的拧紧 21 或拧松。当螺丝孔有脱扣现象时,不准扩大孔径,要在加铆套重新套丝扣后才能使用。

第3条

气球组的胶皮破裂、活塞芯子老化时应更新,气球组的排气嘴、进气嘴与球的接触面老化时,应涂胶水密封或更换新品。

第4条

检修干燥管组时,应把管组一端胶管折住,将另一端水柱计高度加压到700毫米,要求1分钟内水柱不下降,否则应排除故障。常见的故障和排除方法有:胶管老化、有裂纹,更换新品;干燥管本身有裂纹,更换新品。更换硅胶时,两端要垫脱脂棉,下端厚10毫米,上端厚5毫米:两端若垫海绵,下端厚15毫米,上端厚10毫米。

第5条 二氧化碳吸收管组气密性的检查与干燥管组一样。常见的漏气原因和故障排除方法有:胶质垫圈老化,更换新品;金属螺盖开焊,应重新焊接。管的端面不平或呈马蹄形,要用钢锉或砂纸研磨,直至密封良好为止。管本身老化,出现裂纹、螺丝滑扣,更换新品。

第6条

检修气室时,要求气室不漏气、不串气,内表面呈黑色。清洗气室时,将平面玻璃加热后垂直取下,气室的胶装面要作标记;气室腔和弯管要清洗干净;包角螺丝、气室外表要擦干净,安装时胶量要适当,要求即胶装牢固,又看不出多余胶剂。装完后应进行气密性试验。

第7条 检修调微组时,要检查螺杆与连接座是否紧密柔和,要求每次检修要进行清洗,并检查固定连接座的螺丝是否松动。

第8条

检修开关组,在出现诸如按钮弹不起、按钮接触片相碰造成灯泡长明或开关座出现裂纹、螺丝滑扣、电接触片锈蚀等情况时,应重整丝扣或打磨、调整弹簧、调整电接触片等进行检修或更换新品。

第9条

下光源组常见故障用排除方法有:灯泡损坏要更换;灯泡接触环上的螺丝锈蚀或松动,应用砂纸打磨或柠紧;灯泡绝缘圈松动,即便把压紧圈拧到底还不能压紧灯泡,可用粘合剂把灯座绝缘圈粘牢;出现电路短路若是灯泡接触环与灯座连接筒中间有金属屑时,应将其清除干净。

第10条 目镜组常见故障及排除方法有:保护玻璃划伤严重或破碎,应就换新品,新换的保护玻璃用虫胶或指甲油粘牢,粘胶时,涂胶不可过多,以免影响透光,要待胶干燥后方可使用;当旋转目镜末擦拭干净,有赃物,应分解目镜组,取出接目镜并将其擦拭干净,装配时两镜片的鼓面相对,并且镜头平面要与光轴垂直。

第11条 在检修分划板时,若旋转目镜头赃点不随之转动,说明分划板上有赃物,22 是实点,说明赃物在有刻线一面;是虚点,则赃物在另一面。擦拭分划板时,不得用酒精、苯、乙醚等有机溶液擦拭,以免损坏刻线四周的漆层。当分划板与底座脱落时,应用虫胶或指甲油粘合,粘合时有刻线的一面应朝上,并与底座同心。

第12条 盘形管组要畅通,气密性要良好。检修时,将气球一端与盘形连接,压瘪气球若在10秒钟内鼓起,即认为通气良好。

第13条 检修各镜片组时,各镜片要擦拭干净,没有灰尘、指印。擦拭时,可用小竹签卷上脱脂棉轻轻擦拭镜片表面,擦拭的手指只能拿住镜头毛面;不得用金属工具进行擦拭,以免划伤镜面。擦拭中可用脱脂棉沾上少许酒精或苯、乙醚等溶剂进行擦拭,然后用脱脂擦干。

第14条 找光谱的方法是:各镜片检修合格并按要求装好后,将粗动手轮拧到底再反转两周左右,使反射棱镜座与壳体平行;接通电源,使光通过聚光镜射向平面镜,调整灯泡、聚光镜光屏、平面镜使平面镜射出的最亮的一束光与瓦斯室螺丝孔右侧相切,其高度与上螺丝孔相平;移动反射棱镜,光谱即可出现在目镜里。

五、检修时应注意以下问题:

1、各镜片不得有影响光谱的划痕、掉块,平面镜、折光棱镜、反射棱镜的镀膜部分必须完好,物镜不得开胶;否则一律更换新品。

2、装配平面镜时,平面镜的下部和后部要与镜座靠紧,固定压板的两螺丝的压力应相同,松紧适度;如果用弹片固定,弹片应位于镜片中部,以免镜片受力不均影响光谱。

3、装配折光棱镜组时,两支柱的高度要相等,弹片位置应在镜片中部,压板的两个螺丝应松紧适度、压力相同。两个偏心垫圈要夹靠住镜片,以使镜片前表面与镜座上的档片靠紧。

4、反射棱镜组的镜座底部由于调零螺杆和长期顶压,会出现麻点、凹坑等,应用平板油石研磨,使之平整。弹簧片弹性减弱或失效时,可将其翻过来再用或更换新品。装配时镜片后面与镜座应靠紧,以防松动。

5、测微玻璃弹簧片的弹性减弱或失效时,可调整弹簧片的形状以增大弹性,或更换新品。

6、各镜片安装要紧密牢固,方位、角度端正,光线能以正确角度通过。各镜片底座严禁锉磨。干涉条纹宽窄不合适时,可通过调整平面镜组衬垫锡铂纸来解决。

六、光学瓦斯检定器的校验

基本误差的规定是:用水柱计给瓦斯室加压时,根据下式计算不同的甲烷浓度所对应的水柱高度。Δp=0.182r(273+t)式中 Δp─水柱高度,毫米;

x─甲烷浓度,%;

t─校正室温,摄氏度。

逐点反复校正3次,其基本误差对不同量程的仪器应不超过规定。

瓦斯监测工操作规程

一般规定

第1条 瓦斯监测工负责管辖范围内的矿井通风安全检测装置的安装、调试、维修、校正工作。

第2条 瓦斯监测工应将在籍的装置逐台建帐,并认真填写设备及仪表台帐、传感器使用管理卡片、故障登记表、检修校正记录。

安装维护

一、地面检修前得准备工作

第1条 应备有必要的工具、仪器、仪表,并备有设备说明书和图纸。

第2条 按规定准备好检修时所需要的各种电源、连接线,将仪表通电预热,并调整好测量类型和量程。

二、地面检修步骤

第1条 隔爆检查的步骤是:

1、按国际“GB3836.1-83 爆炸性环境用防爆电气设备”检查设备的防爆情况。

2、检查防爆外壳内外有无脱落、油漆脱落及锈蚀严重现象,要求应无此类情况。

3、清除设备内腔的粉尘和杂物。

4、检查连线腔和内部电器元件及连接线,要求应完好齐全,各连接插件接触良好,各紧固件应齐全、完整、可靠,同一部位的螺母、螺栓规格应一致。

5、检查设备绝缘程度。水平放置兆欧表,表线一端接机壳金属裸露处,另一端接机内接线柱,匀速摇动表柄,若读数为无限大(∞),表明绝缘合格。

6、接通电源,对照电源原理图测量电路中各点的电位,判断故障点,排除故障。第2条 通电测试各项性能指标的内容包括:

1、新开箱或检修完毕的设备要通电烤机,经48小时通电后分三个阶段进行调试:(1)粗调。对设备的主要性能做大致的调整和观察;(2)精调。对设备的各项技术指标进行调试、观察和测试;

(3)检验。严格按照设备出厂的各项技术指标进行检验,如发现问题则按本工种第15条的方法处理,通电要从问题处理完后重新开始计算。

2、烤机完毕,拆除电源等外连接线,盖上机盖,作好记录,入库备用。

三、井下安装前的准备工作

第1条

根据要求确定安装位置和电缆长度。

第2条

设备各部件应齐全、完整,电缆应无破口,相间绝缘及电缆导通应良好,并备足安装用的材料。

第3条

瓦斯校准气样的配制应采用煤炭工业技术监督主管部门确认的装置和方法制备甲烷与空气的混合气体,不确定度应小于5%。制备所用的原料气应选用浓度不低于99.9%的高纯度甲烷气体。

四、井下安装

第1条 设备搬运或安装时要轻拿轻放,防止剧烈震动和冲击。

第2条

敷设的电缆要与动力电缆保持0.3米以上的距离。固定电缆用吊钩悬挂,非固定电缆用皮带或其他柔性材料悬挂,悬挂点的距离为3米。

第3条 敷设电缆时要有适当的驰度,要求能在外力压挂时自由坠落。电缆悬挂高度应大于矿车和运输机的高度,并位于人行道一侧。

第4条

电缆之间、电缆与其他设备连接处,必须使用与电气性能相符的接线盒。电缆不得与水管或其他导体接触。

第5条

电缆进线嘴连接要牢固、密封要良好,密封圈直径和厚度要合适,电缆与密封圈之间不得包扎其他物品。电缆护套应伸入器壁内5~15毫米。线嘴压线板对电缆的压缩量不超过电缆外径的10%。接线应整齐、无毛刺,心线裸露处距长爪或平垫圈不大于5毫米,腔内连线松紧适当。

第6条

传感器或井下分站的安设装置要符合有关规定。安装完毕,在详细检查所用接线、确认合格无误后,方可送电。井下分站预热15分钟后进行调整,一切功能正常后,25 接入报警和断电控制并检验其可靠性,然后与井上联机并检验调整跟踪精度。

五、井下维护

第1条 每7天对检测设备进行一次调试校正。

第2条 在给传感器送气前,应先观察设备的运行情况,检查设备的基本工作条件,应反复校正报警点和断电点。

第3条 送气前要进行跟踪校正,应在与井下取得联系后,用偏调法在测量量程内从小到大、从大到小反复偏调几次,尽量减小跟踪误差。

第4条 首先用空气气样对设备校零,再通入校准气样校正精度,锁好各电位器。给传感器送气时,要用气体流量计控制气流速度,保证送气平稳。

第5条 定期更换传感器里的防尘装置,清扫气室内的污物。当载体催化元件活性下降时,如调正精度电位器,其测量指示值仍低于实际的甲烷浓度值,传感器要上井检修。

第6条 设备在井下运行半年后,要上井进行全面检修。第7条 排除故障时应注意以下问题:

1、应首先检查设备电源是否有电。

2、可用替换电路板的方法,逐步查找故障。

3、应一人工作,一人监护。严禁带电作业。并认真填写故障处理记录表。

六、便携式仪器的维护

第1条 必须按产品使用说明书的规定对仪器进行充电。第2条 每隔7天对仪器的零点、精度、报警点进行一次调校。

监测微机员操作规程

一、上机前的准备工作

1、进入机房要穿洁净的工作服、拖鞋,不得将有磁性和带静电得材料、绒线和有灰尘得物品带进机房。

2、必须严格执行交接班制度和填报签名制度。交接班内容包括:设备运行情况和故障处理结果;井下传感器工作情况、断电地点和次数;瓦斯变化异常区的详细记录;计算机的数据库资料。

二、上机操作

1、操作值班人员必须熟悉监测微机的供电、稳压系统情况,注意供电电压不准超过规定范围(160——250V)。

2、一旦因故发生中断死机,首先关断UPS所有负荷,检查电源供电情况,确认电源正常后,依次送电,主机-CRT-调制解调器,复位后,启动运行KJ4监测监控程序。

3、本系统不设自动打印设置,打印机要一般处于停电状态,以减少UPS电耗,打印前打印机再启动送电。

4、井下测点地址、参数变更后,要及时修改定义地址、参数、高报值、高控值,并及时修改报表定义。

5、备用机要处于停机待机状态,需启动时,一定要注意UPS电源负荷情况,防止电源超负荷导致死机。

6、停电的顺序是:主机→显示器、打印机等外围设备→不间断稳压电源→配电柜电源。

7、送电顺序是:配电柜电源→不间断稳压电源→打印机、显示器等外围设备→主机。

8、监控主机、备用机不允许运行其它光盘、软件,严禁在主、备用机上读写、拷贝其它程序。

自救器发放工操作规程 一、一般规定

第1条 自救器工负责范围为:自救器的收发、保管、检查和维修。

二、自救器的收发与管理

第2条 收发自救器时,要轻拿轻放,严禁碰撞;收回的自救器要擦干净,并进行外观检查,放回原处。

第3条 自救器由矿集中管理,实行专人专用,对号发放。

第4条 对在用的自救器应逐台建帐、登卡,即记录自救器的出厂日期、编号、检查日期、检查内容、检查结果、使用者的姓名、开启原因、使用效果等。

第5条 对使用过的自救器要及时注销并补充。凡封条破坏或已开启过的自救器,无论使用时间长短,都应报废;未使用过的自救器,存放时间长达5年以上的,也应予以报废。第6条 自救器不得和易燃易爆品放置在同一库房内。自救器库房必须通风良好,整洁干燥,不得有腐蚀性气体或蒸汽。库房中的自救器应避免放在日光直射或其它热源直接辐射的地方。

第7条 交接班时,要把自救器使用情况、损坏程度交接清楚。分管的自救器帐、卡、物必须相符。

三、自救器的检查与验收

第8条 矿收到厂家发来的自救器后,必须在一个月内由自救器工配合供应部门对外观(包括铭牌、出厂日期和标重)、气密性和称重(仅指过滤式自救器)进行验收,发现产品不符合标准时,应及时与厂家联系退换。

第9条 过滤式自救器的称重检查应使用经过校正误差不超过±1克的天平,增重超过10克的自救器应予以报废。

第10条 使用ZJ型气密检查仪检查过滤式自救器气密性时,要求在15秒内压力计水柱下降不得大于8毫米;用60—65摄氏度稳水检查时,不得有冒泡漏气现象。否则要更换胶圈或进行维修,以保证气密合格。

第11条 在60—65摄氏度温水中进行隔离式自救器气密检查时,自救器浸入水中出现连续冒泡,或浸入水中一分钟内(10秒后开始记数)断续冒泡超过8个的,要及时进行维修。1年内,经检查低于8个泡的,可不进行气密性维修;期满1年时,都要及时维修。

第12条 用温水检查自救器后,必须把自救器擦拭干净。

四、使用ZJ型气密仪检查自救器的操作

第13条 使用的气密仪必须经过调试、检查,要求仪器系统本身是气密的。第14条 气密仪的工作压力范围为(480~520)×9.81帕,检查自救器时,可将压力计水柱提高到540毫米。封压后10秒钟,水柱保持不动时,则认为气密仪调试合格。

第15条 将被试自救器放入气密仪的工作室中。如果检查过滤式自救器,须预先在工作室里放置随机附带的L型填块。

第16条 盖上气密仪封盖,扣上风压钩,同时按秒表计时,计下10秒钟时压力计水柱的高度;25秒时,再次计下压力计水柱高度。对于过滤式自救器,如果在最后的15秒钟内压力计水柱下降不超过8毫米,则认为气密性合格;超过8毫米或压力计水柱高度未达到470毫米的,则认为气密性不合格。对于隔离式自救器,如果在最后的15秒钟内压力计水柱下降不超过30毫米,则认为气密性合格;超过30毫米或压力计水柱高度未达450 28 毫米,则认为气密性不合格。为提高检查效率,封压10秒钟后,若压力计水柱停留在480毫米以上某一高度不动,则认为自救器气密性合格,不必再观察后15秒钟。

第17条 气密性合格的自救器可以继续使用;气密性不合格的自救器必须进行处理。

五、检查自救器时的注意事项

第18条 被检查的自救器应处于气密仪检查场所2小时后,才能开始检查,检查时环境温度的波动不应超过2摄氏度。

第19条 被检查的自救器及气密仪应避免日光直射或靠近暖气热源,检查场所应尽可能避免有过堂风或受抽、排气设备的影响。

第20条 被检自救器上的煤粉和赃物应擦掉,不允许赃物和煤粉等落到密封环和托盘上,以保证气密仪系统的可靠密封。

第21条 若扣上风压钩后,压力计水柱很快下降到400毫米以下,说明自救器大漏气;如怀疑气密仪系统本身的气密性,可换用库存不漏气的自救器作对比试验,不可冒然调整气密仪。

第22条 使用气密仪时,加压(扣封压钩)、卸压(松开封压钩)均应缓慢地进行,切不可猛扣、快放,以防止水溅到工作室里,使机件受损。

第23条 检查自救器时,如发现压力计水柱有上升现象,说明橡胶密封环不好;如在后15秒钟内压力计水柱上升高度超过4毫米,则橡胶密封环应予更换。

第24条 压力计刻度管里出现水泡时,表明压力计缺水,应注水后再用。第25条 自救器检查完后,应立即取出,不可长时间放在气密仪工作室里加压。第26条 对气密处于不合格边缘的自救器,应进行复查。

第27条 对气密性不合格的过滤式自救器,应在经校正误差不超过±1克的天平上称重,增重不超过10克的,密封后可继续使用。

第28条 为了寻找漏气部位,可用直观方法寻找,也可用毛笔沾浓度适当的肥皂水在自救器被加压30~60秒后涂抹于可能漏气的部位进行检查,冒泡处即是漏气处。此方法同样适用于隔离式自救器。

第29条 使用气密仪检查隔离式自救器时,如果在后15秒钟内压力计水柱高度下降15~30毫米,属小漏气,仍属气密合格,但应将漏气处用锡焊封闭;如在最后15秒钟内,压力计水柱高度下降30~50毫米,属中等漏气,经试验还未失效的,补漏维修后可继续使用。

第30条 要详细记录修理过的自救器的损坏与修理情况。

第31条 维修自救器的工作场所应清洁,以避免粉尘、油脂等进入自救器。

通风木工操作规程

一、门制作前的准备工作

1、工作前应把需用工具、材料准备齐全。

2、井上制作风门的操作要求

3、风门扇用单层或双层木板制成。单层木板厚度不小于35毫米,双层木板门中间要加衬垫。

4、风门扇要穿带,上下两条门带规格要相同、平行不歪扭,且距门扇上下两头均留有一定间距。

5、风门扇安装使用前要加装铁门带(大型风门扇可到井下现场组装),既要与木门带平行地装2条规格相同的铁门带,铁门带应长于木门带,靠门轴的一端应伸出一定距离,并卷成折页式圆筒。

6、风门扇必须进行防腐处理。

二、井上木工操作注意事项

1、电锯、电刨必须由经过技术培训且考试合格的人员操作。工作时,应思想集中,确保安全。

2、应掌握木工房备有的灭火器材的使用方法。

3、烘干木料时,不得脱离工作岗位,应经常检查火势及木料干燥程度,干燥后即速取出。

4、禁止在木工房内吸烟、生火炉;特殊情况必须生火炉时,要制定安全措施,并报上级批准。

5、木工房的材料要摆放整齐,工作完毕后,杂物要清扫干净,特别是火炉周围,离开前应有专人检查,火炉熄灭后方可离开。井下风门安装、维修前的准备工作

6、安装、维修风门前,必须检查巷道顶板情况,做到安全施工。在主要运输巷道中安装、维修风门时,要注意来往车辆,必要时应先与有关单位联系。

7、门框倾斜角度要符合要求,以保证安装的风门开关灵活。

8、井下使用的风门、调节风门等必须定期检查,发现问题及时维修。

9、一般应关闭风门进行维修,必要时可摘下风门扇到安全地点维修,但禁止两道风门同时打开。

10、维修风门时,要检查电缆孔、管路孔是否堵严,凡不用的孔口及调节风窗口要及时封堵严密。调解风量窗口处应备有足够的、合格的调节板。

11、拆除回收风门、木板墙、调节风门等木制品时,必须先检查巷道安全情况,应在安全情况下回收。

12、木板、门框及立柱上的铁钉要全部拔出,无法拔掉的必须打平,防止刺伤人。

防灭火检查工操作规程

一、防灭火检查员必须经过培训,应掌握瓦斯检查、测风、测压、测氧及测定一氧化碳、二氧化碳、硫化氢的技术,熟悉通风系统,掌握必要的安全知识。

二、检查时要带齐瓦斯检定器、各式风表、一氧化碳检定器、测压仪器、温度计、尺子、记录簿等。

三、检查火区及可疑发火的地点时,必须2人同行,并且进入检查地点后,应先检查风流上风侧的瓦斯及一氧化碳浓度,然后逐步检查下风测,按顺风方向进入检查区域。

四、对于采空区密闭、废弃巷道、盲巷等,应以检查甲烷、二氧化碳为主,当温度升到35摄氏度以上或闻到火灾气体时,以检查一氧化碳为主;对于未灭的火区和已熄灭的火区、高温点,以检查一氧化碳为主;火区密闭要检查墙温、气温、水温及各种气体浓度的变化,重点掌握一氧化碳浓度变化。

1、检查密闭前先将观察孔堵头去掉。

2、将仪器对准观察孔进行换气,后按规定进行检查。并做好记录。

3、检查完毕后要及时把观察孔堵上。

4、采集气样时,先将观察孔打开,然后用气球进行采集,直到气球充满为止。

5、采集完成后及时封闭观察孔。

五、检查时,发现有人工作的地点或回风流中一氧化碳浓度超过24ppm时,要将人员 31 撤出,在适当地点设好栅栏,并向通风区及矿调度汇报。

六、高冒地点应挂牌管理,按规定进行检查,检查时要用长把工具,发现温度高于常温且有上升趋势或有微量一氧化碳时,应增加观察次数,并向有关领导汇报,以便采取有效措施。

七、应每月填写反映火区检查情况的“火区检查日志”,重点情况记入“火区卡片”,填绘火区示意图,连续检查时,当班检查的情况应向下班交接清楚。

瓦斯泵工操作规程

1、启动真空泵前,必须检查进、排管路气门及防爆器的水位,符合要求,方准启动。

2、启动真空泵的操作顺序是:关闭总进门及泵进气门,打开放空气门,向泵注入一定量的水,然后启动真空泵,待泵运转正常后,再按顺序打开泵进气门和总进门,并调整气水分离器供水的阀门,使分离器内的水面稳定在水注计上给定的高度。

3、当沼气浓度低于30%时,应关闭用户闸门,停止向用户输送以保安全。

4、要注意检查电动机的温度,检查真空表的数字变化以及水箱、气分离器的水位。真空泵要经常注油。电机和真空泵有异常响声和真空表有大幅度变化,要立即停泵,查明原因进行处理。

5、每小时检查一次泵房内空气的浓度,检查电机与泵对轮附近的沼气,当沼气浓度达0.5%时要立即停泵。

6、停泵的操作顺序是:先关闭用户气门和总排气门后,打开短路气门排出泵内瓦斯,然后关闭泵进气门停泵。

7、认真做好记录,每半小时检查记录一次,沼气浓度,抽放负压、流量、大气压、温度等数据。

8、运转中突然停电,应先断开电源,然后再按停泵顺序进行操作。

9、泵房门禁止生明火和吸烟。

观测、放水工操作规程

1、入井前,应根据当天的工作任务和目标带全所需工具、仪器,并保证完好。

2、如需进入栅栏内工作,必须两人前后同行,并随时检查巷道内瓦斯。瓦斯超过规定时,应停止进入,请示后再采取措施。

3、采用仪器气泵检查管道内瓦斯时,应连续挤压泵(即一鼓起立即再捏扁)。在挤压5~6次后,在气泵复原的瞬间立即将仪器的进气口从管道内拔出。

4、检查管道瓦斯浓度时,必须检查两次以上,发现差别较大时,应检查其原因进行处理。

5、抽放瓦斯钻孔及分路观测点必须悬挂观测记录牌,并注明观测地点和孔号。每次观测后,应将有关参数填写在记录牌上,并保证牌板、记录和报表三对口。

6、管路巡查放水时,应随时观察管路、放水器的气密性,发现问题及时处理。放水器放水时,应首先关闭放水器上边分支闸门,然后打开放水闸门,待水放完后,及时关闭放水闸门,然后打开分支闸门。

7、自动放水器应定期检查、维护,对无法使用的自动放水器,要及时更换。

8、观察、放水工上井要定期填写管路检查、维护、放水和钻场测定记录。

钻工操作规程

1、钻机安装应牢固,变速箱及油箱内的油位应合适,安全防护罩及防尘盖必须齐全。

2、各部分操作手把应处在正确位置。

3、调试钻机时,要求各转动部分运转应正常,开关启动应灵活可靠。钻机空载运行10分钟。确认无问题后,方可接上钻杆、钻头,接通水源,由司机操作开始钻孔。

4、利用操作台的操作手把来控制钻杆的旋转和推进。操作手把由空挡位向前推动时,钻头顺时针方向旋转,进行钻孔或安装钻杆,操作手把由空挡位向后拉时,钻头反时针方向旋转,可拆卸钻杆;

5、推移给进油缸的操作手把可控制钻头前进或后退,向前推时钻头前移,向后拉时钻头后退;

6、需快速推进或后退时可操纵快速操作手把,操作方式与给进油缸相同,即前进拉后退;

7、利用节流阀门控制行进速度,手柄顺时针方向移动时速度加大,反时针方向转动时速度减小,钻进时可根据岩性随时调节节流阀,加大或减小推进压力。

8、接管或卸管时,必须把钻杆扶正,并对好丝扣,接头要拧紧,漏水时要缠绕止漏,每次接拆钻杆时,钻扣必须停电。

9、有喷煤水和瓦斯的钻孔或水力冲孔时,工作面前方必须打好立柱,并用20毫米发以上的木板搭接好,保护人体安全。

10、设有专人检查瓦斯,当风流中沼气浓度达1%以下时,停止送电,达1.5%时停止钻机运行进行处理,待沼气浓度降到1%以下时才准开动钻机。

11、严重喷煤水、喷瓦斯的钻孔要设置三通管,将喷出的煤水和瓦斯用管子引对20米以外的回风道中。

12、钻机电气设备的防爆性能必须良好,控制开关,必须放在全负压通风的新鲜风流中。

13、发现塌煤卡钻、不回水或孔内压力升高时,要停止推进,前后移动钻杆,不得停钻、停水,待孔内煤水和瓦斯喷出压力缓和后才可继续钻进。有塌孔卡钻的钻孔,当班内必须完毕,并将钻杆全部启出。

封孔工操作规程

1、封孔前,首先用高压风把孔内的煤粉吹净,然后用水冲洗,用高压风排粉时,人员必须站在钻机一侧,不得站在钻机正前。

2、封孔工必须严格按质量标准化要求进行封孔,封孔深度:岩孔不小于3m,煤孔不小于5m。即用两根1“钢管,中间用管箍连接做封孔管。

3、将孔内先下入6米1”封孔管,同时下入一根长4.3m(孔外余0.3m)直径为1/2"mm的橡胶注浆管,下入孔内的长度为0.6m,孔外的剩余长度以与注浆泵能联接上为宜。里段1.4m用聚氨脂封孔,聚氨脂两种材料要搅拌均匀,倒在塑料袋上,塑料袋在封孔管上要捆绑牢固。

4、用加有速凝剂的灰沙比为1:3的混凝土,将孔口外段500mm内封堵严实。也可用石膏粉拌和清水制成膏状对孔口500mm进行封闭,要求封严填实,孔口周围600mm内煤壁用清水冲洗干净后用石膏满敷,孔口封堵后静置45分钟以上,待石膏凝固后才能进行注浆操作。

5、浆注浆管接到注浆泵上,搅拌水泥沙浆,其中石膏、水泥、水比例为2.5:10:5,水泥沙浆搅拌好以后,即可开泵注浆。

6、当注到排气管向外跑浆时,说明孔内已经注满灰浆,然后用铁丝浆排气管扎住,继续注浆使灰浆渗入煤壁,当煤壁往外渗水冒气泡时,即可停止注浆。

安装工操作规程

1、安装工必须能够识别和看懂矿井瓦斯抽放系统图、注浆系统图及清水系统图。

2、安装工安装管路之前,必须将所用螺丝、胶垫、三通等零件携带齐全。

3、安装工安装管路之前,必须仔细检查施工地点的瓦斯浓度及巷道顶板支护情况,发现隐患必须及时处理,只有在确保安全的前提下方可施工。

4、安装工进行管路安装必须严格按集团公司质量标准化要求进行严格施工,螺丝、胶垫必须上齐、上牢,直巷不得用弯管接,根据巷道情况该加偏口的加偏口。管路吊挂距底板不得少于300mm,且平稳、满足直面要求。

5、工作必须密切配合,起吊搬运重物时,工作人员要动作协调一致,以免发生事故。

6、安装工安装好管路后,必须将用不完的螺丝、胶垫及其它零件及时回收上井,严禁在井下乱扔、乱放。

7、安装工必须定期巡回检查管路,新管安装时做到防锈,各种管子的接口、衬垫要达到质量标准化,使水管、浆管、瓦斯管不漏水、不漏浆、不漏气,符合设计要求。

8、安装工必须将各种备用品存放整齐,室内外和工作场所要保持清洁卫生,搞好文明生产。

制浆工操作规程 一、一般规定

1、灌浆工负责操作泥浆泵等机具给采空区和火区注浆。

2、制浆工工作前必须穿胶靴、工作服、带手套。

3、制浆工进班后应认真检查制浆机、电气设备是否完好,如有问题必须及时处理。

4、开搅拌机前一人操作一人监护。

5、开水枪时,人员必须站立安全位置,以防击伤人。

6、水枪距土不得少于5m,水枪前方如有裂隙或松动的土,先用水枪冲下,防止塌方伤人。

二、地面工作

(一)、灌浆前的准备工作

第1条 制浆前所用各种设备应完好;各阀门应处在正确的开关位置;供水系统应畅通;照明设备应齐全;各岗位人员应到齐上岗。

第2条 制黄泥浆前应将冲土用的水枪放到合理位置,并联接好供水管路。第3条 制浆前,首先将浆池底清理干净,将遗留的脏杂物清扫出去,关闭下浆孔和泻水孔闸门。

(二)、置备黄泥浆的操作

第1条 用水枪冲土时,水枪操作人员要不断摆动水枪;采土要均匀,使冲下的土充分湿润,防止大块土进入泥浆池。采土结束后,将水枪及管路中的水放干净,并放到固定的地方,以便下次再用。

第2条 开动搅拌机进行搅拌的同时用比重计检查泥浆浓度,并调整到要求的水土比。第3条 下浆孔要提前下好篦子,灌浆过程中要随时清理草根、树皮、石子及其他赃物,防止下浆时堵孔,堵管。

(三)灌浆注意事项

第1条 制浆人员要时刻注意注浆设备运转情况,当注浆设备运转出现异常时要立即停机,进行检查处理。

第2条 接到井下准备灌浆的电话后,首先给水冲洗管路(或钻孔),当井下第二次来电话通知井下管路流水已畅通时,方可开始灌浆。

(四)停机后需要做的工作

第1条 接到井下停浆电话后,要立即关停搅拌机,并关好灌浆管路的阀门,然后给水冲洗管路(冲洗时间一般不超过20分钟),清洗冲刷灌浆池。冬季要把水枪和管路中的水放静。

第2条 工作结束后,要核实本班灌入的实土量,并将本班工作详细记入“灌浆日志”。

第3条 下班前应做好场地清理工作,并按要求管理好设备,保证注水池有足够的水量。

注浆工操作规程

第1条 灌浆工要了解工作范围内的管路系统(包括管径、接头方式、阀门型号、安装地点等);准备管钳、扳手、丝锥、钳子、铁丝等工具材料。

第2条 灌浆工到达工作地点后,首先检查管路系统状况,发现问题及时处理;然后检查灌浆地点的顶、帮支护情况,有不安全因素立即处理,处理不了要汇报区队领导,禁止蛮干。

篇3:通风队各工种操作规程

瓦斯检查员操作规程

一、入井前对瓦检仪进行检查

1、首先要对瓦检仪的外观进行检查,对瓦检仪的目镜盖、主调螺旋盖、皮套、背带、胶管、吸气球和水分吸收管等进行检查,是否完好。

2、对水分和二氧化碳吸收管内的药品进行检查,要求药品装满、颗粒均匀,一般约2--5mm左右。水分吸收管内装硅胶时正常为深蓝色,失效为粉红色。如内装氯化钙时正常为纯白色,失效后成浆糊状,后变成固体。二氧化碳吸收管内装钠石灰,正常为粉红色,失效后变为粉白色。

3、检查仪器的气密性,用手捏扁吸气球,另一手堵住吸气球的进气孔,气球不胀起,表明仪器气密,否则进行分段检查。

4、对仪器的电路和光路系统检查,电路系统:分别按下光源开关和微读数开关,由目镜和微读数观测窗内观察,以灯泡亮、松手即灭为好。光路系统:按下光源电钮,由目镜观察,并旋转目镜筒,看干涉条纹是否清晰,否则进行调整或更换仪器。

二、瓦检仪换气调零

1、在进风大巷、石门等作业地点,温度相近的新鲜风流中对瓦检仪进行换气。

2、换气时,接好二氧化碳吸收管,手压气球5-6次,然后转动测微手轮,将仪器微读数盘回到零位,再转动调零手轮,将干涉条纹中某条黑线与分划板零位相重合,对零后上好仪器护盖。

三、瓦斯检查

1、进入检查区域后,按巡回图表所拟定的路线及时间依次到达各检查地点。

2、一手将连接瓦斯入口的胶管用探杖伸向测点(距巷道顶板200mm以下处)手压气球5-6次,待测气体进入气室然后收回探杖,打开目镜护盖,观察光谱黑线在分划板上移动的位置,同时调整测微手轮,使光谱黑线在分划板上移到靠近整数位置上,再观察测微刻度盘上指示的读数,然后将分划板上指示的整数与测微盘上指示的小数相加即为该点的沼气浓度。四、二氧化碳检查

在距测定点距巷道底板200mm以上处,首先测出该点的瓦斯浓度,然后拔开二氧化碳吸收剂管,将仪器吸气孔伸向同一地点,同测瓦斯方法一样测出二氧化碳和瓦斯混合混合气体浓度数值,减去已测出的同一地点瓦斯浓度,再乘以0.955所得的数即为该点的二氧化碳浓度。

五、检查后的工作

1、检查后及时填写记录手册,告知现场负责人,或班组长。

2、零点班瓦检员第一次填写牌板时,要将前一天检查的数据全部擦净,然后依据本班检查结果填写,标明日期、时间、检查人。

3、检查完后要及时向通风调度、队部进行班中汇报。

六、特殊问题处理

1、盲巷要严格按有关规定进行管理,如果进入盲巷检查瓦斯或二氧化碳时,要携带氧气鉴定器(便携仪),边走边检查。当瓦斯、二氧化碳达到3%或氧气浓度低于18%时,停止前进立即退出,设好栅栏、警标,汇报通风调度。

2、主要通风机突然停电、停风,要及时切断电源,并通知受影响区域人员,撤到进风巷中,向通风调度汇报,按指示进行工作。

3、发现局部通风机停电、停风,要将局部通风机通风地段的人员撤到全风压供风巷道中,在巷道口设置警标,并向通风调度汇报。

4、发现瓦斯积聚或超限,立即通知超限区域人员停止作业,切断电源,撤出险区,在通向超限区域的所有入口处设置警标,并查明原因及时汇报通风调度和值班队干,待接到通风调度指示后,方可按指示排放瓦斯,当班不能排放时,要在现场同下班交接。

5、如发现风流异常,要查明原因,及时汇报通风调度。

七、交接班

1、接班人员到达接班地点时,应主动向接班人交待当班的瓦斯检查情况及本班所存在的问题,并在交班薄上填写清楚。

2、当班工作情况与接班人员交清后,相互在手册上签字。

3、升井后先到通风调度汇报当班各点的瓦斯及当班工作情况,并填写有关记录、台帐。

测风工操作规程

1、测风工必须熟练掌握各种风表的使用方法,测风应在测风站进行;

2、入井前必须根据测风任务带好所用的风表、秒表、瓦斯检查器、皮尺、记录本及其他有关仪器并检查是否完好,不完好不得入井。

3、选择临时测风地点测风时,应选择在巷道无空顶、空帮、支护完好、无淋水,前后10m无拐弯、无分岔、无障碍物的地点。

4、根据巷道风速大小选用不同风速的风表,当风速超过每秒10m时选用高速风表,风速在每秒0.5~10m时选用中速风表,风速在每秒0.5m以下时选用微速风表。

5、测风前,先将风表的计数器指针回零。在测风断面内背靠巷道壁站立,一手拿秒表,一手拿风表,将手臂向风流垂直方向伸直,风表叶轮迎向风流并与风流垂直,在断面内均匀移动,待叶轮转动30s后再同时启动风表计数器和移表进行测定。测定结束时同时关闭。每个测风断面至少测3次,取平均值。

6、测风时,测风人员可采用路线法或定点法测定。用定点法测风时,测风人员背向巷道帮,右手持风表并向右侧前方伸直,手臂和身体胸面成105°~110°的角度,测风时速度要均匀,风表距巷道周壁为0.2m左右。巷道断面在10m2以上时测120s,巷道断面在4~10m2时测60s。用路线法测风时,风表在测风断面内按规定线路、规定时间内匀速移动,根据断面大小,分四线法、六线法和迂回八线法。如下图所示:

7、测风时为保证测量精确移动速度要尽量均匀。

8、测完风速后,开始测量巷道断面,测量该点的温度、瓦斯及二氧化碳浓度(测量瓦斯及二氧化碳方法同瓦检员)。

9、测量完毕后及时将风表读数代入风表校正曲线公式计算出实际风速,将风速乘以巷道断面得出实际风量。

10、将所测得该点风速、风量、温度、瓦斯、二氧化碳等数据记录在测风本、测点记录牌上并填写清楚日期、姓名。

11、一个系统测完后,预算一下所测数据是否可靠,如个别点闭合差距较大,应分析原因重新补测。

12、测风时如发现风流不稳定,应查明原因,将问题处理后再重新测定。

13、测风员在井下行走和测风时,要注意顶板、车辆、机器等,保证自身安全。

测尘工操作规程

一、地面作业

1、采样器检查:检查流量是否符合要求,电量是否充足,利用秒表检查定时器。

2、采样盒检查:采样盒和滤膜夹不干净时,应用酒精棉球擦干净。

3、分析天平检查

(1)滤膜准备:滤膜称量,用镊子取下滤膜两面的夹衬纸,置于分析天平称量至恒量,并编号记录重量。

(2)滤膜固定:旋开滤膜固定圈,可先用酒精棉球擦净。

(3)用镊子夹取已称过的滤膜,毛面向上平铺在锥形环上,再将固定盖套上并拧紧。

(4)检查安装的滤膜有无皱褶与漏缝,若有时重固定。

(5)将装好的滤膜固定圈收入样品盒内备用,直径75mm的滤膜(漏斗形)固定法。

①旋开滤膜固定圈。

②用镊子将滤膜对折折两次成90°角的扇形,然后张开成漏斗状,置于固定盖面,脱出时应重装。

③用固定玻璃棒将滤膜漏斗的锥顶推向对侧,在固定圈的另一方向形成滤膜漏斗。

④检查安装的滤膜有无漏缝,若有应重装。⑤将装好的滤膜固定圈放入样品盒中备用。

二、井下作业

1、选择测点:采样地点设在回风测,采样高度在人的呼吸带,一般为1.5m左右。掘进工作面采样时,应在巷道未安装风筒的一侧距装(岩)煤、打眼或喷浆等地点4~5m处进行。在机械化采煤工作面,应在采煤机回风侧,距采煤机10~15m处进行。采煤工作面多工序同时作业时,应在回风侧距转载点3m处进行。在其它产尘场所采样时,在不妨碍工人操作的情况下,采样地点尽可能靠近工人作业的呼吸带。

2、采样

(1)测点选定后,将三角架支稳,采样头正面迎向含尘风流,高度以距地板1.5m为宜。当迎向含尘风流无法避免飞溅的泥浆、砂砬对样品污染时,受尘面可以侧向。

(2)根据采样点粉尘浓度大小,选用不同规格滤膜采样,粉尘浓度小于50mg/m3时,选用40mm直径的滤膜样,粉尘浓度在50mg/m3以上时,选用75mm直径的滤膜样。

(3)取出准备好的滤膜夹,迅速装入采样头中拧紧螺盖,启动电源开关,迅速调解节流量旋钮,使流量保持在20L/min时,开始记时,并随时调解流量使其保持稳定,时间到自动停止。对连续性生产作业,应在生产达到正常状态5min后再进行采样,对间接性生产作业,应在工人作业时采样。

3、采样后的作业

(1)采样完毕,拧开采样头,用镊子将滤膜夹轻轻拿出,放入原来的采样盒中,记录采样地点、采样盒编号及防尘状况。

(2)测尘完毕后,按《通用标准》有关要求妥善携带,保护好有关测尘器具及时升井。

三、采样称量、计算、记录

1、升井后,到测尘室将采有粉尘的滤膜用镊子从采样盒中取出,放入干燥器2h后放入分析天平称量,并及时做好记录,称量后再放入干燥器中干燥30min再一次称量,当相邻两次质量差不超过0.1mg时,取其最小值。

2、各样品粉尘浓度计算以后,要及时将采样编号。把重量、流量、时间、作业性质、有关措施、采样时间等填入测尘记录本,并填好该测尘点防尘状况,以便分析。

3、按要求及时做出测尘报表,审批后送交有关部门及领导。

四、直读式粉尘浓度测量仪使用方法

1、使用前准备

(1)滤膜夹和滤膜的准备。应将滤膜裁剪到合适的宽度,然后用滤膜夹把滤膜夹好,应保证滤膜不露出滤膜夹的边缘,并且保证滤膜的平展。

(2)将三角架稳定地放置到采样点上,然后将测尘仪固定于三角架上,并使采样头对准逆风方向采样。

(3)开机,按“开”键,打开仪器电源,显示器显示公司标志、名称及200s的倒计时,并进行初始化,初始化完成进入主菜单。主菜单分为:测量、数据、校正和设定四个子菜单,选中子菜单按“确定”键即可进入。

2、开始测量

(1)在主菜单中选定“测量”菜单后按“确定”键进入,并把空白滤膜放入滤膜夹中,然后将装有滤膜的夹插入测量腔中。

(2)选择“

1、空白”,进行空白膜的测量,按“确定”键测量完毕,蜂鸣器会发出“嘀”的一声,表示测量完毕。此时会显示电参量(电参量是指仪器传感器的检测信号经过转化后的仪器示值,不能等同于质量值)结果,再按任意键返回测量菜单。

(3)接着把滤膜从测量腔中取出来,插入采样头的滤膜固定处,然后旋紧采样头。在测量菜单中选择“

2、采样”,按“确定”键进入。根据待测环境的粉尘浓度的高低,设定采样时间(0.1--99.9分钟),再回到测量菜单,粉尘浓度高时可将采样时间减少,反之可增加采样时间。按“确定”键进行采样,此时仪器开始进行采样,泵开始工作,采样完毕仪器发出“嘀”的一声提示采样结束。

(4)采样结束后程序自动返回测量菜单,一只手捏紧滤膜夹,另一只手将采样头旋松,取出滤膜夹,将滤膜夹的迎尘面朝上,再次插入测量腔中,此时选“

3、测尘”按“确认”键进入,测量时间出厂已经设定好,用户无须改动。测量时间结束后显示带尘滤膜电参量数值,三秒钟后显示此次测量结果和测量时间,同时自动存储数据。

通风设施工操作规程

1、通风设施工必须经过专业技术培训,考试合格后,方可上岗。

2、通风设施工需要掌握以下知识:(1)熟悉矿井通风系统,避灾路线。(2)掌握下井须知等有关安全规定。

(3)熟悉矿井通风构筑物(永久风门、临时风门;调节风窗;测风站;风桥;永久密闭、临时密闭)的作用、安设方法和要求。(4)了解有关煤矿瓦斯、煤尘爆炸的知识。(5)掌握《煤矿安全规程》对通风构筑物的规定。

(6)掌握《煤矿通风安全质量标准化标准》通风设施部分的规定。(7)了解井下各种气体超限的危害及预防知识。

3、通风设施的施工,必须按照施工设计,在设计位置施工,设计要符合有关规定,不得随意改变安设位置、种类。

4、须使用设计的材料,不得随意更改。

5、密闭外的钢轨、电缆、管路必须断开。

6、在架线巷道中进行有关工作时,必须先和有关单位联系,在停电、挂好”有人工作,不准送

电”的停电牌、设好临时接地线及保护好架线后方能施工。施工完毕后方可取下临时地线,摘下停电牌,合闸送电。

7、施工人员随身携带的小型材料和工具要拿稳,利刃工具要装人护套,材料应捆扎牢固,要防止触碰架空线等其他物品。

8、在运输巷道中施工风门要设警示牌并有专人指挥来往车辆,做到安全施工。

9、每个风门前后5m内的支护保证完好,并应清理剩余材料,保持清洁、通畅。

10、每个密闭前5m内的支护保证完好,按规定要求设置栅栏并挂密闭说明牌。

11、行车的两道风门间距不少于两列车长度,行人的两道风门间距要大于5m。

12、风门必须能够自动关闭;两道风门之间安设联锁装置,保证不能同时打开。

13、通风设施竣工后,要组织验收,凡是不符合质量要求的,必须整改至合格。

14、密闭、风门、风桥等通风设施的位置应选择在顶帮坚硬、末遭破坏的煤岩巷道内,尽量避免设在动压区。

15、在有电缆线、管路处施工时,要妥善保护电缆、管路,防止碰坏。需移动高压电缆时,要事先与机电部门取得联系。

16、掏槽只能用大锤、钎子、手镐、风镐施工,不准采用爆破方法。

17、作业高度超过2m时,要搭脚手架,佩带保险带,并制定安全措施。作业前准备

18、密闭、风门、风桥、测风站等通风设施施工前要认真学习工作通知书和相关的知识。

19、准备施工需用的材料和工具。

20、计划所需的材料,并将材料装车,装运材料要有专人负责。各种材料装车后均不能超高、超宽,装车要整齐,两头要均衡。

21、料车人井前必须与矿调度室及有关单位联系,运送时应严格遵照材料运输的有关规定。

22、井下装卸大型材料时要互相照应,互相配合。材料要靠巷帮整齐堆放,不得影响运输、通风、行人。

23、材料卸车时,应现场验收,发现不足或有误,须及时更正。

24、检查施工地点的瓦斯、二氧化碳等有害气体的浓度并在作业地点合适的位置设置有害气体便携式检测仪器,随时监测作业地点有害气体浓度。操作顺序

25、本工种操作应遵照下列顺序进行::验收材料→清理操作现场(安全检查)→施工→质量检查→清理操作现场。

监测监控工操作规程

1、监测系统的安装、维护由专职监测监控工进行,监测监控工必须经过技术培训,懂得仪器的工作原理、结构、日常维护,能熟练作业。

2、要对入井设备的完好状况及功能认真检查,确保入井设备性能完好。

3、仪器在搬动、安装、拆卸时要小心谨慎,不要摔碰,不要强行拉扯连线,要轻拿轻放,防止剧烈振动和冲击,以免损坏脆弱元件和线路板开焊。

4、井下监测电缆的敷设要有适当的驰度,要与动力电缆保持0.3m以上的距离,悬挂点的间距不大于3m。电缆之间、电缆与设备之间的连接必须符合防爆标准要求。

5、井下分站应设置在便于人员观察、调试、检验及支护良好、无滴水、无杂物的进风巷道或硐室中,安设时应加垫支架,使其距巷道底板不小于300mm或吊挂在巷道中。

6、瓦斯传感器应垂直悬挂,距顶板(顶梁)不得大于300mm,距巷道侧壁不小于200mm。风速、压差、温度、一氧化碳传感器应悬挂在能正确反映该测点值的地点。设备开停传感器应安设在负荷侧电缆上。

7、安装完毕,详细检查接线正确与否,确认无误后方可送电。井下分站预热15分钟后进行调整,分站、传感器工作稳定后方可接入报警和断电控制并检验其可靠性,然后与中心站联机跟踪检验其精度。

8、要经常擦拭仪器上的煤尘,特别是探头进气孔上的煤尘,防止堵塞气孔,影响气体进入探头气室,定期清扫气室中污物。

9、仪器初安装五天内,要每天检查稳流,精度报警、断电点等。

10、仪器正常工作后,每周检查调整一次主机稳流源输出电流(催化元件的工作电流);检查和调整差放零点、机零点,检查和调整接收机和主机的跟踪、报警点;检查和调整主机断电点、指示精度。

11、仪器在井下运行半年后,要将其回至井上进行全面清洗、擦拭、烘干,然后进行试运行,完好后方可再下井使用.其中甲烷传感器要送安全检测中心进行检定。

12、遥测仪使用一定时期后,催化元件活性要下降,当精度电位器调到头,而主机指示仍低于实际的瓦斯含量而又无别的故障时,要更换新的催化元件,更换时,需把探头拿到地面,在更换后进行调试。

13、发现仪器工作不正常而又不能及时修理时,要及时查明原因,向矿调度室、通风队值班室、通风监测室汇报后,要整机更换,旧机要及时打上井修理。

14、建立健全各项台帐、记录、图纸、报表。

监测监控机房操作员操作规程

1、进入机房要穿整洁的工作服、拖鞋,不得将有磁性和带静电的材料、绒线及有灰尘的物 品带进机房,要经常用干燥的棉纱擦拭设备外壳,每班定期清扫室内卫生。

2、机房操作必须严格执行交接班制度。交接班内容包括:(1)设备运行情况和故障处理情况;

(2)井下监控分站、传感器工作状况、风电瓦斯闭锁工作情况;(3)瓦斯、一氧化碳、温度变化异常区的详细记录;(4)计算机网络系统运行情况。

3、接班后,首先要对瓦斯、一氧化碳较大的区域进行监控数据详细了解,并详细跟踪监视,发现异常情况及时向通风调度汇报。

4、中心站值班人员,发现瓦斯超限等异常情况,要立即通知矿调度室和相关单位,并做好记录;对系统发生的所有异常情况,要做详细记录,以便追查处理。

5、安全监控系统网络信息设备,要保持正常运行,如发现设备故障,要及时处理,并做好运行记录。

6、与井下监测工协调配合进行监控设备的校正和故障处理工作。

7、值班员必须按时打印监测日报表,对异常信息要注明原因及处理措施,并按要求报送相关领导审阅签字。

8、中心站监控主备计算机不得用于与监控无关的操作。运行的计算机要定期维护,监控主备机应定期交替运行,一般情况下倒机时间不超过两个月。

9、送电顺序是:配电柜电源→不间断稳压电源→打印机→显示器等外围设备→主机。送电前应将所有设备的电源开关置于停止位置,严禁带负荷送电。

10、停电顺序是:主机→显示器等外围设备→打印机→不间断稳压电源→配电柜电源。

通风仪器标校工操作规程

1、仪器标校工必须经过专业培训,经考核合格后持证上岗。

2、仪器标校工必须掌握通风常用仪器的结构、性能、工作原理、保养和一般性故障排除等基础知识。

3、仪器必须按说明书要求定期标校:

4、标校方法:用2%的标准甲烷气样,通过流量计注入仪器标校孔,通过流量计进行控制。

5、标校时,要用光学瓦斯检定器核查标准甲烷气样含量。

6、建立仪器标校记录,每次标校都要进行登记。并根据管理仪器总台数和使用班次,排好标校时间计划。

7、标准气样的使用、保管与维修:

(1)使用气样钢瓶时,首先卸下钢瓶封口螺丝,旋上带有快速接头的调节器,打开气瓶开关,旋上计量计接头,调节至需要流量。

(2)气样的保护与维修

①气样钢瓶属高压容器具类,严禁猛烈撞击和日光下曝晒。

②产品应放置在通风干燥室内,并无腐蚀性物品存在。

③气样钢瓶勿与氧气钢瓶等助燃性气体混放在一起。

④气样钢瓶要定期进行压力试验。

⑤标准气瓶要定期进行压力试验。

⑥气样使用完毕后,接口部分必须擦拭干净,防止灰土尘粒落入,影响气流畅通。

⑦标校人员必须执行交接班制度,把当班未完成的工作向接班人交代清楚。

8、光学瓦斯检定器每月标校一次,便携式瓦斯检测报警仪每周标校一次。

9、仪器标校室内严禁闲杂人等进入。

10、仪器标校室内严禁烟火。

11、仪器标校室内要保持清洁。

12、气样、仪器仪表按规定放置,不得乱堆乱放。

仪器仪表发放工操作规程

1、仪器发放工必须经过培训,经考核合格后,持有效证件上岗。

2、必须熟悉各种仪器的结构、性能、使用方法。

3、发放工负责仪器仪表发、收及检查维护工作。

4、对仪器仪表逐台建帐,做好记录。

5、接班时对仪器仪表的数量进行核对。

6、必须对待发仪器进行检查,确保灵敏可靠。

7、收回的仪器要详细检查完好状态,对损坏的及时通知仪器检修工修理,并做好记录。

8、不完好仪器仪表禁止发放。

9、必须严格执行交接班制度。

10、发放仪器时轻拿轻放,注意力集中,以免仪器滑落造成人员伤害、仪器损坏。

11、仪器发放室要保持清洁,避免仪器仪表接触污浊气体和有腐蚀性的物体造成仪器损坏。

12、灵敏度高的仪器仪表应有专门存放的盒子、放置在规定的位置避免因保管不当造成仪器仪表灵敏度下降。

13、仪器发放室严禁闲杂人等进入。

14、仪器发放室内严禁吸烟。

15、仪器发放工不得私自拆卸、维修仪器仪表。

16、各种仪器仪表要用专用的充电器进行充电,不得混用。

17、仪器应及时充电,保证电量充足。

18、仪器仪表发放工要保持仪器仪表的清洁。

材料员

1、材料员要明确自己的工作职责和权利。

2、物资到货要进行数量和质量的验收,监督和检验货品数量、质量。

3、采购入库的物资不符合要求,或规格、单价、数量不符,材料员有权拒绝入库。对于劣质物品提出拒收和退货。

4、物资入库后按材质和规格分类、有序存放,贴标签或说明牌,库存物资要做到心中有数。

5、对库存物资建立帐本、出入库手续完备、每月盘点,做到帐物相符。

6、妥善保管各类物品、摆放整齐、防止积压霉烂丢失。

7、加强物资帐目管理,做到进、出、存相符,手工账目与电脑账目相符,严格按管理权限发放材料,做到帐目日清月结,物资月盘点要实事求是。

8、加强“四防”防范措施,做到人走、灯关、门锁,经常性的检查库房内的设施,发现隐患及时上报。

9、日常工作中要做到库内无灰尘,保持清洁卫生。

10、腐蚀性物品要单独存放,并采取措施保证腐蚀性的气、液体不泄露。

11、计划、领取区队常用物资,保证库存数量满足区队正常使用。

12、保证个人劳保按时、按量发放。

13、做好班组领用材料记录,已被考核班组材料节支。

14、个人使用的工具按规定发放,建立工具发放台帐;对库房中使用、损坏的设备、工具及时联系维修、更换,填写维修记录。

15、库房内严禁烟火,存放易燃易爆物品要采取必要的防范措施。

篇4:连铸各工种操作规程

一:进入现场必须穿戴好一切劳防用品。二:及时了解和掌握交接班的安全动向。

三:仔细检查液压站设备,吹氧皮带,备用油缸,吊索具是否处于良好状态。四:对各种电器设施进行常规检查,并配合电工送电做好现场监护工作。五:大包放置平稳,对准中包后方可开浇。

六:钢包开浇时,应注意钢流不要过急,避免钢水溅出伤人。

七:测量钢水温度时,注意力要集中,热电偶要干燥,必须一人测温,严禁其他人员围在钢包周围。

八:大包工应经常检查大包平台安全栏是否牢固,以防坠落。九:取样时,样模要干燥,样壳不要随意乱

十:大包回转台非工作状态,必须转正与厂房平行方向。

十一:液压站发生故障立即关机,迅速通知检修人员处理并做好故障处理时的现场监护工作。

十二:大包关不住或漏包,穿水口事故无法继续浇铸时,应立即通知周围人员闪开,迅速开动回转台将大包转到事故上方。

十三:大包回转台内部设备设施检修时,必须提醒检修人员在操作台上挂警示牌,检修完毕确认无人检修时,方能操作。

连铸主控工岗位职责及操作规程

一:浇钢时,一切报警设备和有关指示灯处于工作状态。送引錠前必须检查所有仪表是否处于正常状态。

二:在生产过程中认真观察各工序的工作运作情况,发现异常及时向机长或调度汇报,同时真实填写好生产原始记录。

三:若遇大包或中间包穿包漏钢事故或发现结晶器进出水不正常及其它设备运转不正常时,应及时通过广播通知有关人员注意。

四:当突然发生断电,停水事故时,要立即启用事故备用水源。五:结晶器断水时,应立即通知浇钢工采取措施。

六:停送各类冷却水时,要与相关单位配合好,并实行确认制度。七:禁止非本岗位及无关人员点击电脑鼠标,不许用微机娱乐。八:设备出现故障,应及时通知机长和相关人员。九:主控室内应保持三班清洁文明交班。

十:禁止用湿布抹计算机及各类仪表及电气设备。

连铸浇钢工岗位职责及操作规程

一:树立“安全第一,预防为主”的思想,保证安全。二:严格执行中包操作相关的工艺制度和工艺要求。

三:协助机长完成本班生产任务及各项指标,负责中包浇铸过程中,一般生产事故的预防及处理工作。

四:负责平台中包区域的环境卫生,定置管理工作。五:配合机长做好班建工作,完成车间下达的各项工作。六:加强对射源棒的保护,并由专人(机长)负责。

七:浇铸中结晶器一旦停水,不允许重新送水,应立即停止浇铸,防止穿结晶器发生爆炸。

八:接班穿戴好劳动用品,提前10分钟上岗,了解上班生产及设备运行情况。九:检查平台中包区设备及操作箱开关,按钮显示灯是否正常。十:装备好本班生产的工具,及辅助材料。

十一:检查结晶器不得有渗、漏水现象,铜管内壁光滑无>1.5mm划伤,流量、压力及进水温度正常。

十二:检查振动台架是否有冷钢及杂物,振动平稳。十三:检查二冷水压、水温、、流量、噴嘴是否正常。十四:检查中包平车行走,升降对中机构是否灵活可靠。十五:检查中间包及浸入水口烘烤是否符合工艺要求。

连铸切割工岗位职责及操作规程

一:工作前穿戴好个人防护用品,带好防护罩。

二:负责氧气、乙炔阀门,检查皮管是否有漏气现象,发现漏气及时处理。三:严格执行氧、燃气压力及定尺工艺要求,精心操作。四:切割系统发生故障负责排除或配合维修处理。五:配合出坯把钢坯及时开出。

六:人工切割所用乙炔瓶,氧气瓶应远离火源(10m以外)。

七:人工切割时,切割工必须佩戴面罩和电焊手套,严禁用布和带油的手套,不准用切割枪吹扫工作区和设备及衣服上的灰尘。八:检查切割机时,所有人员严禁吸烟或动用明火。

连铸出坯工岗位职责及操作规程

一:负责出坯液压系统翻钢机,摧钢机,辊道的运转。二:保持室内整洁,文明交班。

三:操作时认真检查操作台上按钮,信号灯,转换开关等是否好用,否则应及时通知有关人员处理。

四:生产过程中,发现出现异常,要及时通知有关人员修理。五:工作结束时,必须将所有的开关回零位。

上一篇:反特权思想、特权现象自查自纠报告下一篇:八下古诗词鉴赏